Amine Functionalized Noble Metal: Metal Oxide Nanohybrid for Efficient Electrochemical Determination of 25-Hydroxy Vitamin-D3 in Human Serum

Abstract: Quantification of 25-hydroxy vitamin-D3 (25-OHVD3) is important because its deficiency is related to numerous diseases, including osteoporosis, depression, diabetes, heart disease, certain autoimmune conditions, and even Covid-19. In the present study, noble metal-metal oxide nanohybrid based on L-cysteine functionalized gold decorated zirconia nanoparticles (Cys-Au@ZrO2 NPs) were synthesized with the objective of enhanced electrochemical behavior, stability, availability of functional group to covalently bind… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 42 publications
0
3
0
Order By: Relevance
“…Therefore, for the best of our knowledge, our work presents the higher number of serum samples analyzed than any other experimental electrochemical immunosensor available in literature and, among the validated ones, the one exhibiting the lower limit of detection. MPA/Au DPV 20-200 ng ml −1 10 ng ml −1 0.16 A ml ng −1 cm-2 [6] CAEF/RCP* Chronoamperometry 10 -100 ng ml −1 10 ng ml −1 0.16 μA ml ng −1 cm −2 [40] nCeO2/CC** DPV 1-200 ng ml −1 4.63 ng ml −1 2.08 μA ml ng −1 cm −2 [41] Cys-Au@ZrO2/ITO DPV 1-50 ng ml −1 3.54 ng ml −1 2.01 μA ml ng −1 cm −2 [42] CD-CH***/ITO DPV 10-50 ng ml −1 1.35 ng ml −1 0.2 μA ml ng −1 cm-2 [43] Asp-Gd2O3NRs/ITO DPV 10-100 ng ml −1 0.10 ng ml −1 0.38 μA ml ng −1 cm-2 [11] Fe3O4-PANnFs/ITO DPV 10-100 ng ml −1 0.12 ng ml −1 0.90 μA ml ng −1 cm-2 [10] CYM@AuMNPs DPV 7.4 -70 ng ml −1 2.4 ng ml −1 0.55 μA ml ng −1 cm-2…”
Section: Calibration and Clia Correlationmentioning
confidence: 99%
“…Therefore, for the best of our knowledge, our work presents the higher number of serum samples analyzed than any other experimental electrochemical immunosensor available in literature and, among the validated ones, the one exhibiting the lower limit of detection. MPA/Au DPV 20-200 ng ml −1 10 ng ml −1 0.16 A ml ng −1 cm-2 [6] CAEF/RCP* Chronoamperometry 10 -100 ng ml −1 10 ng ml −1 0.16 μA ml ng −1 cm −2 [40] nCeO2/CC** DPV 1-200 ng ml −1 4.63 ng ml −1 2.08 μA ml ng −1 cm −2 [41] Cys-Au@ZrO2/ITO DPV 1-50 ng ml −1 3.54 ng ml −1 2.01 μA ml ng −1 cm −2 [42] CD-CH***/ITO DPV 10-50 ng ml −1 1.35 ng ml −1 0.2 μA ml ng −1 cm-2 [43] Asp-Gd2O3NRs/ITO DPV 10-100 ng ml −1 0.10 ng ml −1 0.38 μA ml ng −1 cm-2 [11] Fe3O4-PANnFs/ITO DPV 10-100 ng ml −1 0.12 ng ml −1 0.90 μA ml ng −1 cm-2 [10] CYM@AuMNPs DPV 7.4 -70 ng ml −1 2.4 ng ml −1 0.55 μA ml ng −1 cm-2…”
Section: Calibration and Clia Correlationmentioning
confidence: 99%
“…Existing work mostly utilizes the antigenantibody binding approach for sensing or employs costly catalysts such as Au, Pd etc. 5,[7][8][9] An economically viable and stable point-ofcare sensor would require a detection platform free of enzymes, antibodies, and aptamers. Also, almost all of the existing work focuses on Vitamin D as the analyte instead of 25OHD.…”
mentioning
confidence: 99%
“…7 However, the focus has been mainly on D 3 as it was found to be more potent and effective than D 2 . 9 Vitamin D sensors also suffer from electrode fouling caused by strongly adsorbed oxidation products.…”
mentioning