Ambulatory measurement of respiratory sinus arrhythmia and respiration rate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
229
0
2

Year Published

2001
2001
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 255 publications
(244 citation statements)
references
References 53 publications
3
229
0
2
Order By: Relevance
“…HR was measured by the Vrije Universiteit Ambulatory Monitoring System (VU-AMS) continuously from the time series of R wave to R wave intervals derived by a three-lead ECG. Reliability and validity of the VU-AMS have been described previously [18,19]. Continuous HR was recorded during a session with four different conditions, always applied in ®xed order: lying, sitting, standing and walking.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…HR was measured by the Vrije Universiteit Ambulatory Monitoring System (VU-AMS) continuously from the time series of R wave to R wave intervals derived by a three-lead ECG. Reliability and validity of the VU-AMS have been described previously [18,19]. Continuous HR was recorded during a session with four different conditions, always applied in ®xed order: lying, sitting, standing and walking.…”
Section: Methodsmentioning
confidence: 99%
“…The ecological validity of the intermittent HR from the ABP recordings was further examined in an ambulatory experiment. During three different days, 109 male white-collar workers wore the ABP monitor, together with a device that continuously records HR from the ECG [18,19]. Continuous ECG-derived HR (ECG-HR) was averaged over periods of time with ®xed posture and physical activity.…”
Section: Introductionmentioning
confidence: 99%
“…The following three points were automatically scored and marked on the average dZ/dt waveform, (1) B-point or upstroke, (2) dZ/dt (min) , and (3) X-point or insicura. From these points, the pre ejection period (PEP) was obtained, which is defined as the time between the onset of ventricular depolarization (Q wave onset) and the onset of left ventricular ejection of blood in the aorta (B-point) (De Geus, Willemsen, Klaver, & Van Doornen, 1995). Because of the limited reliability of B-point detection, due to ambiguity in the location of the B-point, each dZ/dt waveform was checked and corrected or deleted when automated scoring revealed B-points that were morphologically inconsistent (Riese et al, 2003).…”
Section: Physiological Measuresmentioning
confidence: 99%
“…DOI 10.1002/dev FIGURE 1 Episodes of the separation-reunion procedure including separation (sep) and reunion (reun) with parent (P) and stranger (S). (Grossman, Van Beek, & Wientjes, 1990) which combined the respiratory time series and the inter beat intervals (IBI) to calculate the shortest inter beat interval during heart rate acceleration in the inspiration phase, and the longest inter beat interval during deceleration in the expiration phase (De Geus et al, 1995). RSA was defined as the difference between the longest and the shortest IBI.…”
Section: Physiological Measuresmentioning
confidence: 99%
“…Peripheral psychophysiological activity was assessed with the validated Vrije Universiteit Ambulatory Monitoring System (VU-AMS, Vrije Universiteit, Department of Psychophysiology, Amsterdam, Netherlands) Model 5 FS by recording electrocardiography and impedance cardiography with a sample rate of 1000 Hz (De Geus & van Doornen, 1996; De Geus, Willemsen, Klaver, & van Doornen, 1995; Riese et al, 2003; Willemsen, De Geus, Klaver, van Doornen, & Carroll, 1996). The VU-AMS calculated interbeat intervals (IBIs) to assess the heart period between adjacent R-R signals.…”
Section: Methodsmentioning
confidence: 99%