1990
DOI: 10.1097/00004728-199007000-00018
|View full text |Cite
|
Sign up to set email alerts
|

Alveolar Echinococcosis of the Liver

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
21
1

Year Published

1995
1995
2016
2016

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(23 citation statements)
references
References 0 publications
1
21
1
Order By: Relevance
“…During the examinations, the animals were anesthetized with 1.5% isoflurane in O 2 , and respiration was monitored. Imaging was performed using flash 3D vibe (TE/TR 1.14/20 ms, FoV 59×70 mm 2 , matrix of 162×192, slice thickness 0.36 mm) and T2-weighted turbo-spin echo (TE / TR = 40/3000 ms, FoV ¼ 60 Â 60mm 2 , matrix of 320×320, slice thickness 1.5 mm) sequences for volume measurements and detection of extrahepatic and vascular infestation, characterization of multivesicular structures of the metacestodes, as well as delineation of necrotic host and parasite tissue as it has been detected previously in human cases (Claudon et al 1990;Duewell et al 1990). The scanner operates under the syngo MRI software (Siemens Medical Solutions, Germany) for image acquisition, and Inveon Research Workplace software (Siemens Preclinical Solutions, Knoxville, Tennessee, USA) was used to analyze the MR images and to perform volumetry.…”
Section: Bioassaysmentioning
confidence: 99%
“…During the examinations, the animals were anesthetized with 1.5% isoflurane in O 2 , and respiration was monitored. Imaging was performed using flash 3D vibe (TE/TR 1.14/20 ms, FoV 59×70 mm 2 , matrix of 162×192, slice thickness 0.36 mm) and T2-weighted turbo-spin echo (TE / TR = 40/3000 ms, FoV ¼ 60 Â 60mm 2 , matrix of 320×320, slice thickness 1.5 mm) sequences for volume measurements and detection of extrahepatic and vascular infestation, characterization of multivesicular structures of the metacestodes, as well as delineation of necrotic host and parasite tissue as it has been detected previously in human cases (Claudon et al 1990;Duewell et al 1990). The scanner operates under the syngo MRI software (Siemens Medical Solutions, Germany) for image acquisition, and Inveon Research Workplace software (Siemens Preclinical Solutions, Knoxville, Tennessee, USA) was used to analyze the MR images and to perform volumetry.…”
Section: Bioassaysmentioning
confidence: 99%
“…Magnetic resonance imaging (MRI) has formerly played only a minor role in the diagnosis of hepatic lesions (including AE) due to higher costs, longer time of investigation and restricted availability [9,10].…”
Section: Introductionmentioning
confidence: 99%
“…Previous studies comparing the above imaging techniques showed that no imaging technique was uniquely superior [9][10][11][12][13]. US proved advantageous due to its ubiquitous availability, easy handling, cost-effectiveness and lack of radiation.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…While these modalities mostly provide satisfactory information about the disease in endemic areas, as in ours, further diagnostic investigative tools, such as biopsies, may be needed in non-endemic regions [7][8][9].…”
Section: Discussionmentioning
confidence: 81%