2019
DOI: 10.1038/s41598-019-53573-9
|View full text |Cite
|
Sign up to set email alerts
|

Aluminosilicate Nanocomposite on Genosensor: A Prospective Voltammetry Platform for Epidermal Growth Factor Receptor Mutant Analysis in Non-small Cell Lung Cancer

Abstract: Lung cancer is one of the most serious threats to human where 85% of lethal death caused by non-small cell lung cancer (NSCLC) induced by epidermal growth factor receptor (EGFR) mutation. The present research focuses in the development of efficient and effortless EGFR mutant detection strategy through high-performance and sensitive genosensor. The current amplified through 250 µm sized fingers between 100 µm aluminium electrodes indicates the voltammetry signal generated by means of the mutant DNA sequence hyb… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
9

Relationship

5
4

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 38 publications
0
8
0
Order By: Relevance
“…When the oligoaptamer was immobilized on the CDI-Cu NF, stretching of (PO 4 ) 3− (the sugar-phosphate backbone of DNA) was observed at 1082 and 1230 cm −1 35 , 36 . The hydrogen bonds of the DNA strands are notable from 3000 to 3500 cm −1 37 . Upon detection of target β-lactoglobulin, the peak of the amide is observed to be in the range of 1566–1742 cm −1 .…”
Section: Resultsmentioning
confidence: 99%
“…When the oligoaptamer was immobilized on the CDI-Cu NF, stretching of (PO 4 ) 3− (the sugar-phosphate backbone of DNA) was observed at 1082 and 1230 cm −1 35 , 36 . The hydrogen bonds of the DNA strands are notable from 3000 to 3500 cm −1 37 . Upon detection of target β-lactoglobulin, the peak of the amide is observed to be in the range of 1566–1742 cm −1 .…”
Section: Resultsmentioning
confidence: 99%
“…First, the electrode pattern was designed by AutoCAD software. 29 , 30 The sensor surface was organized by two electrodes with multiple junction triangles at equal micro gap distances. The following steps were used to prepare the electrode.…”
Section: Methodsmentioning
confidence: 99%
“…The calculated LoD of the aluminosilicate modified genosensor is 100 aM. In addition, a voltammetry interdigitated electrode (IDE) was developed to sensing genomic DNA hybridisation using microscale aluminium electrodes and gaps [122].…”
Section: Other Biosensorsmentioning
confidence: 99%