2008
DOI: 10.1002/jps.21244
|View full text |Cite
|
Sign up to set email alerts
|

Alternative Measures of Lipophilicity: From Octanol–Water Partitioning to IAM Retention

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
71
0
5

Year Published

2008
2008
2017
2017

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 134 publications
(78 citation statements)
references
References 153 publications
(192 reference statements)
0
71
0
5
Order By: Relevance
“…As the shake-flask method is time-consuming and less susceptible for automation, (Giaginis and Tsantili-Kakoulidou 2008), immobilized artificial membrane (IAM) chromatography was introduced as a more rapid, efficient, reliable and accurate measurement of lipophilicity (Stewart and Chan 1998). IAM columns contain a monolayer of phosphatidylcholine covalently immobilized on a silica support, which mimics very closely the lipid membrane bilayer (Ducarme et al 1998;Ecker and Noe 2004;Reichel and Begley 1998).…”
Section: Iam Capacity Factormentioning
confidence: 99%
“…As the shake-flask method is time-consuming and less susceptible for automation, (Giaginis and Tsantili-Kakoulidou 2008), immobilized artificial membrane (IAM) chromatography was introduced as a more rapid, efficient, reliable and accurate measurement of lipophilicity (Stewart and Chan 1998). IAM columns contain a monolayer of phosphatidylcholine covalently immobilized on a silica support, which mimics very closely the lipid membrane bilayer (Ducarme et al 1998;Ecker and Noe 2004;Reichel and Begley 1998).…”
Section: Iam Capacity Factormentioning
confidence: 99%
“…The 1,2-dichloroethane/water partition system was one of the reference systems discussed in a recent review article concerning lipophilicy assessment of neutral and ionizable drug molecules. As noted by Giaginis and Tsantili-Kakoulidou [65] an alkane/water or dichloroethane/water system may better simulate biological membranes if no hydrogen bond sites are available. Bouchard et al [66] examined the lipophilicity of zwitterionic drugs based on potentiometric and cyclic voltametric measurements in the 1,2-dichloroethane/water system.…”
Section: Resultsmentioning
confidence: 95%
“…The composition of the mobile phase, MeOH:DMF:Tris-HCl buffer 10 mM pH 7.4 (85:5:10, v/v/v), is the one previously used to test the other members of the series, thus, allowing comparison of the whole series [31,32]. This methodology is widely accepted by medicinal chemists as an alternative method to evaluate experimental lipophilicity [72]. Table 4 summarizes the R M values for each…”
Section: In Vitro Anti-trypanosoma Cruzi Activity and Unspecific Cytomentioning
confidence: 99%