2017
DOI: 10.1002/cmr.a.21429
|View full text |Cite
|
Sign up to set email alerts
|

Alternative data processing techniques for serial NMR experiments

Abstract: NMR measurements are often performed in a serial manner, that is, the acquisition of an FID signal is repeated under various conditions, either controlled (as temperature or pH changes) or uncontrolled (as reaction progress). The traditional approach to process "serial" data is to perform the Fourier transform of each FID in a series. However, it suffers from several problems, in particular, from the need to sample full Nyquist grid and reach a sufficient signal-to-noise ratio in each separate spectrum. The pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 56 publications
(90 reference statements)
0
10
0
Order By: Relevance
“…The quantitative analysis of NUS spectra is known to be possible [Mayzel et al (2017)] if somewhat challenging [Mobli and Hoch (2014), Shchukina et al(2018), Stetz and Wand(2016)]. In order to verify the extracted quantitative information we compared processing with the SMILE package [Ying et al 2017] with other softwares: SCRUB [Coggins et al(2012)] and MDD , ] using coprocessing with additional spectra measured with the same setup of the spectral resolutions and spectral widths (supplementary information material Figure S4).…”
Section: Resultsmentioning
confidence: 99%
“…The quantitative analysis of NUS spectra is known to be possible [Mayzel et al (2017)] if somewhat challenging [Mobli and Hoch (2014), Shchukina et al(2018), Stetz and Wand(2016)]. In order to verify the extracted quantitative information we compared processing with the SMILE package [Ying et al 2017] with other softwares: SCRUB [Coggins et al(2012)] and MDD , ] using coprocessing with additional spectra measured with the same setup of the spectral resolutions and spectral widths (supplementary information material Figure S4).…”
Section: Resultsmentioning
confidence: 99%
“…To measure TCs in a protein, the typical approach is to acquire a series of 2D spectra at different temperatures, either 1 H– 1 H TOCSY for unlabelled samples or 15 N HSQC for 15 N‐labelled proteins. As explained in our recent study, [5] serial measurements of correlation spectra, even those that are 2D, are time‐consuming, due to sampling and sensitivity limitations. These limitations make the measurement of TCs from spectra with more than two dimensions difficult.…”
Section: Introductionmentioning
confidence: 99%
“…It is worth mentioning that there exists a variety of alternative sampling methods applicable to cases, when peaks do not shift over the reaction [7,8] or shift according to a simple model [5,32‐35] . These methods are summarized in our recent review [36] . They are, however, not useful in the general case of a process causing potentially complex variations of spectral parameters.…”
Section: Introductionmentioning
confidence: 99%
“…[5,[32][33][34][35] These methods are summarized in our recent review. [36] They are, however, not useful in the general case of a process causing potentially complex variations of spectral parameters.…”
Section: Introductionmentioning
confidence: 99%