2020
DOI: 10.1016/j.aca.2020.07.019
|View full text |Cite
|
Sign up to set email alerts
|

Alternative coulometric signal readout based on a solid-contact ion-selective electrode for detection of nitrate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
20
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 28 publications
(27 citation statements)
references
References 43 publications
2
20
0
Order By: Relevance
“…Following this type of configuration, Wang and co-workers investigated the use of commercial OMCs as transducers on a SC-ISE for coulometric nitrate detection. 99 The authors reported suitable nitrate quantification with reproducible responses related to the high electrical power of OMCs acting as an electrochemical double-layer supercapacitor (Fig. 4c).…”
Section: Carbon Materials For Sensing Applicationsmentioning
confidence: 94%
“…Following this type of configuration, Wang and co-workers investigated the use of commercial OMCs as transducers on a SC-ISE for coulometric nitrate detection. 99 The authors reported suitable nitrate quantification with reproducible responses related to the high electrical power of OMCs acting as an electrochemical double-layer supercapacitor (Fig. 4c).…”
Section: Carbon Materials For Sensing Applicationsmentioning
confidence: 94%
“…Besides conducting polymers, Qin and co-workers also used a layer of ordered mesoporous carbon as the ion-toelectron transducer for NO 3 − -selective SC-ISEs. 32 Prussian blue was also adopted in the study of the capacitive model to detect Na + . 25 In the case of Pb 2+ selective ISEs, the current response was found to be limited by the ion transport in the conducting polymer layer, which is likely caused by the sequestration of Pb 2+ by PEDOT(PSS).…”
Section: Coulometric Readout Of Solid-contact Ises (Sc-ises) With Con...mentioning
confidence: 99%
“…The glassy carbon (GC) disk electrode with the diameter of 3 mm was carefully polished with 0.05 μm Al 2 O 3 slurry, and then cleaned with ethanol and deionized water under the ultrasonic condition for 2 min, respectively. The OMC suspension (3 mg/mL) was prepared according to the reported literature [26], and then drop cast on the polished GC electrode. After being dried at room temperature, the GC electrode modified with OMC as solid contact (GC/OMC) was obtained for further use.…”
Section: Fabrication Of the Solid-contact Ca 2+ And No 3 − -Isesmentioning
confidence: 99%