2019
DOI: 10.1063/1.5093533
|View full text |Cite
|
Sign up to set email alerts
|

All-optical isotropic scalar 4He magnetometer based on atomic alignment

Abstract: We propose a helium scalar magnetometer based on a triple resonance setup, showing no dead angles, and which can be implemented in an all-optical way. This triple-resonance scheme involves optical pumping with amplitude-modulated light, complemented by a modulated light-shift. Both light beams propagate parallel so that a single optical access to the atomic cell is needed. Experimental results are in good agreement with our theoretical model. The main error sources affecting the magnetometer accuracy are discu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 30 publications
0
7
0
Order By: Relevance
“…Helium magnetometers [ 34 , 35 , 36 , 37 , 38 ] are often used as secondary magnetometers for calibration of FGMs, which are susceptible to long-term drift. Typically V/SHMs have lower size, weight, and power (SWaP) requirements than FGMs.…”
Section: Existing Applicationsmentioning
confidence: 99%
See 3 more Smart Citations
“…Helium magnetometers [ 34 , 35 , 36 , 37 , 38 ] are often used as secondary magnetometers for calibration of FGMs, which are susceptible to long-term drift. Typically V/SHMs have lower size, weight, and power (SWaP) requirements than FGMs.…”
Section: Existing Applicationsmentioning
confidence: 99%
“…A radio frequency (RF) source is used to drive the transition between the Zeeman sub-levels, the resonant frequency of which is determined by the background magnetic field through the relationship , where is the gyromagnetic ratio GHz/T. The amplitude of the resonance signal can be amplified using a population stirring technique where atoms are selectively pumped from metastable Zeeman sub-levels to the P state and subsequently decay back to the metastable state for increased interaction with the incident RF field [ 38 ].…”
Section: Existing Applicationsmentioning
confidence: 99%
See 2 more Smart Citations
“…Helium magnetometers [34][35][36][37][38] are often used as secondary magnetometers for calibration of FGMs, which are susceptible to long-term drift. Typically V/SHMs have lower size, weight, and power (SWaP) requirements than FGMs.…”
Section: Cassinimentioning
confidence: 99%