2018
DOI: 10.1016/j.expthermflusci.2018.06.028
|View full text |Cite
|
Sign up to set email alerts
|

Alkalis atomic emission spectroscopy and flame temperature measurement of diesel impinging flames in an opposed multi-burner gasifier

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 25 publications
0
8
0
Order By: Relevance
“…The optical apparatus consists of an ultraviolet (UV) imaging system (EX-4710B, Isuzu Optics Corp.), a hyperspectral imaging device (HIS-VNIR-OWL1000, Isuzu Optics Corp.), and a high-speed camera (pco.dimax S1, pco.). The UV imaging system includes a 1056 × 1027 pixel UV camera combined with a narrow bandpass filter (310 and 430 nm with a full width at half-maximum (fwhm) of 10 nm); this is a suitable setup as the primary emissions of the OH* and CH* chemiluminescence are produced at the 310 and 430 nm bands, respectively . The single coal particle images are captured by the hyperspectral imaging system, which has a response spectrum of 400–1000 nm and captures an image size of 1024 × 520 pixels.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The optical apparatus consists of an ultraviolet (UV) imaging system (EX-4710B, Isuzu Optics Corp.), a hyperspectral imaging device (HIS-VNIR-OWL1000, Isuzu Optics Corp.), and a high-speed camera (pco.dimax S1, pco.). The UV imaging system includes a 1056 × 1027 pixel UV camera combined with a narrow bandpass filter (310 and 430 nm with a full width at half-maximum (fwhm) of 10 nm); this is a suitable setup as the primary emissions of the OH* and CH* chemiluminescence are produced at the 310 and 430 nm bands, respectively . The single coal particle images are captured by the hyperspectral imaging system, which has a response spectrum of 400–1000 nm and captures an image size of 1024 × 520 pixels.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…The experimental conditions are listed in Table . The coal flow rate was set at 1.5 g/min, and the global equivalence ratio O/C (mol·mol –1 ) was calculated as follows: where m O 2 / m coal represents the mass ratio for the gas flow rate of coal and oxygen. ( m O 2 / m coal ) st denotes the mass ratio where coal is completely consumed.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 3 more Smart Citations