2013
DOI: 10.1016/j.bej.2013.03.016
|View full text |Cite
|
Sign up to set email alerts
|

Alkalinity ratios to identify process imbalances in anaerobic digesters treating source-sorted organic fraction of municipal wastes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
38
0
1

Year Published

2014
2014
2021
2021

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 98 publications
(45 citation statements)
references
References 17 publications
4
38
0
1
Order By: Relevance
“…Certainly there may be other unknown factors that improve the early warning performance of BA/TA in Reactor A. In addition, it is worth mentioning that IA/PA was used to replace VFA/BA in this paper, since these two were almost equivalent (Martín-González et al, 2013), and the threshold of IA/PA was lower than that of VFA/BA, so the warning effect of IA/PA is considered theoretically better than that of VFA/BA.…”
Section: Response Of Process Parametersmentioning
confidence: 90%
See 3 more Smart Citations
“…Certainly there may be other unknown factors that improve the early warning performance of BA/TA in Reactor A. In addition, it is worth mentioning that IA/PA was used to replace VFA/BA in this paper, since these two were almost equivalent (Martín-González et al, 2013), and the threshold of IA/PA was lower than that of VFA/BA, so the warning effect of IA/PA is considered theoretically better than that of VFA/BA.…”
Section: Response Of Process Parametersmentioning
confidence: 90%
“…However, previous researches on early warning parameters always focused on a specific parameter, verified its effectiveness and defined its threshold value (Martín-González et al, 2013;Wang et al, 2009); or studied the responses of multiple parameters under a specific condition, and suggested the optimal parameters for this operating conditions (Nielsen et al, 2007;Kleyböcker et al, 2012;Ahring et al, 1995). Thus, though lots of researches on early warning parameters have been conducted, the proposed early warning indicators are only effective when applied to these specific operating conditions, while less effective in systems with different operation conditions.…”
Section: Introductionmentioning
confidence: 93%
See 2 more Smart Citations
“…The intermediate alkalinity (IA) is the difference between TA and PA and includes mainly the buffering capacity of the VFA [75,76]. The stability of the process can be evaluated by calculating the IA/PA ratio where a ratio of 0.3 or less indicates a stable process [75,77]. A value between 0.3 and 0.8 indicates, on the other hand, a risk of instability and a value above 0.8 suggests instability [49].…”
Section: Ph Is An Important Parameter Influencing Methane Productionmentioning
confidence: 99%