2010
DOI: 10.1117/1.3365959
|View full text |Cite
|
Sign up to set email alerts
|

Alignment procedure for radiation pattern measurements of antenna-coupled infrared detectors

Abstract: An antenna-coupled detector's directional properties can be verified by measuring its angular radiation pattern. At infrared frequencies, this pattern can be measured by rotating the device while illuminating it with a laser beam. An accurate radiation pattern can be measured only if the device is coaligned with the axis of rotation and the focus of the laser beam. In the alignment procedure presented, the device is rotated to various angles and the distance along the orthogonal axis from the current device po… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 13 publications
0
4
0
Order By: Relevance
“…A CO 2 laser operating at 10.6 μm is chopped at 1.5 kHz and focused at F/8 onto the antenna, which is connected to a five axis goniometer [25]. The device is connected to a current preamplifier and monitored with a lock-in amplifier that is referenced to the frequency of the mechanical chopper.…”
Section: Resultsmentioning
confidence: 99%
“…A CO 2 laser operating at 10.6 μm is chopped at 1.5 kHz and focused at F/8 onto the antenna, which is connected to a five axis goniometer [25]. The device is connected to a current preamplifier and monitored with a lock-in amplifier that is referenced to the frequency of the mechanical chopper.…”
Section: Resultsmentioning
confidence: 99%
“…The laser is mechanically chopped at 1.5 kHz and focused at F/8 onto the phased-array antenna, which is connected to a five-axis goniometer [20]. The rectified current from the diode is passed through an external current preamplifier and monitored with a lock-in amplifier that is referenced to the frequency of the mechanical chopper.…”
Section: Resultsmentioning
confidence: 99%
“…In this configuration, the Fraunhofer diffraction pattern of the spatially incoherent field is generated in the focal plane of the F/1 lens [22]. The phased-array antenna is mounted to a five-axis goniometer located in the focal plane of the F/1 lens [23]. The rectified current from the MOM diode is passed through an external current preamplifier and monitored with a lock-in amplifier that is referenced to the frequency of the mechanical chopper.…”
Section: Fabrication and Measurementmentioning
confidence: 99%