1991
DOI: 10.1109/10.81582
|View full text |Cite
|
Sign up to set email alerts
|

Alignment methods for averaging of high-resolution cardiac signals: a comparative study of performance

Abstract: Accurate signal estimation by means of coherent averaging techniques needs temporal alignment methods. A known low-pass filtering effect is yielded when alignment errors are present. This is very critical in the estimation of low-level high-frequency potentials in high-resolution ECG analysis. A comparative study of the performance of three alignment methods (the double-level method, a new time-delay estimation method based on normalized integrals, and matched filtering) is presented in this paper. A real sign… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
48
0

Year Published

1995
1995
2018
2018

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 100 publications
(48 citation statements)
references
References 13 publications
0
48
0
Order By: Relevance
“…The problem is just as obvious because any individual beat-to-beat interval has the potential of being dramatically different from the mean. Therefore, each heartbeat must be segmented using an adaptive approach (Jane et al, 1991). For the ECG, the process is straightforward because the trace contains a number of high frequency components to match.…”
Section: Heartbeat Alignmentmentioning
confidence: 99%
“…The problem is just as obvious because any individual beat-to-beat interval has the potential of being dramatically different from the mean. Therefore, each heartbeat must be segmented using an adaptive approach (Jane et al, 1991). For the ECG, the process is straightforward because the trace contains a number of high frequency components to match.…”
Section: Heartbeat Alignmentmentioning
confidence: 99%
“…The detector is based on an adaptive threshold in the ECG amplitude that has been previously filtered with a band-pass filter (12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22).…”
Section: R Wave Detectormentioning
confidence: 99%
“…For this reason, a 1-kHz sampling rate is used, reducing the low-pass filter effect due to the presence of alignment errors 12 . This fact affects the remaining QT segment contribution in the r(n) signal, which is not only influenced by the correct alignment of QRS pulses, but also by the selected value for the adaptation constant (μ) in the adaptive algorithm.…”
Section: Qt Pattern Cancellationmentioning
confidence: 99%
“…The performance of the alignment methods was evaluated by the standard deviation σ of the alignment error, which is inversely related with the cutoff frequency of an equivalent lowpass filter of the averaged signal [8]. The mean value of σ for all morphologies tested is presented in Table 1 and in Figure 5 for a range of noise levels of white and EMG noise for both temporal and wavelet cross-correlation methods.…”
Section: Resultsmentioning
confidence: 99%
“…For this reason, several alignment techniques have been proposed to search for a precise fiducial point in HRECG records [4], [5], [6], [7]. A complete comparative study of the performance of the different alignment methods was presented in [8].…”
Section: Introductionmentioning
confidence: 99%