Chemical and Biological Standoff Detection III 2005
DOI: 10.1117/12.632114
|View full text |Cite
|
Sign up to set email alerts
|

Algorithms for chemical detection, identification and quantification for thermal hyperspectral imagers

Abstract: Standoff detection, identification and quantification of chemicals in the gaseous state are fundamental needs in several fields of applications. Sensor requirements derived from these applications include high sensitivity, low false alarms and real-time operation, all in a compact and robust package suitable for field use. The thermal infrared portion of the electromagnetic spectrum has been utilized to implement such chemical sensors, either with spectrometers (with no or moderate imaging capability) or with … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(23 citation statements)
references
References 4 publications
0
23
0
Order By: Relevance
“…It is this equation can be used at the detection algorithm of gases. The algorithm of automation gases detection was under development and tests [10,12]. The influence of emissivity coefficient on measurement results can also be compensated by adopting several methods from pyrometric non-contact temperature measurements.…”
Section: Model Of Process Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…It is this equation can be used at the detection algorithm of gases. The algorithm of automation gases detection was under development and tests [10,12]. The influence of emissivity coefficient on measurement results can also be compensated by adopting several methods from pyrometric non-contact temperature measurements.…”
Section: Model Of Process Detectionmentioning
confidence: 99%
“…Finally, results are presented to demonstrate the capabilities and the performances of the remote gas quantification by using hyperspectral data obtained from the Telops HyperCam. The latter is described in much detail in prior references [9][10][11][12].…”
Section: Introductionmentioning
confidence: 99%
“…Finally, results are presented to demonstrate the capabilities and the performances of the remote gas quantification by using hyperspectral data obtained from the Telops HyperCam spectrometer. The latter is described in much detail in the references [9][10][11][12].…”
Section: Introductionmentioning
confidence: 99%
“…It is this equation can be used at the detection algorithm of gases. The algorithms of automation gases detection were under development and tests [10,12]. The influence of emissivity coefficient on measurement results can also be compensated by adopting several methods from pyrometer non-contact temperature measurements.…”
Section: Ifts Fovmentioning
confidence: 99%
“…Dual thresholding approaches have been used for real-time processing, but two detection banks were used instead of BMA as a second pass. 44 …”
Section: Algorithm Complexity Comparisonmentioning
confidence: 99%