2014
DOI: 10.2172/1221044
|View full text |Cite
|
Sign up to set email alerts
|

Airtightness Results of Roof-Only Air Sealing Strategies on 1 �-Story Homes in Cold Climates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2014
2014
2014
2014

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 1 publication
(5 reference statements)
0
4
0
Order By: Relevance
“…Project Overcoat: An Exploration of Exterior Insulation Strategies for 1-1/2 Story Roof Applications in Cold Climates (Ojczyk et al 2013a) determined that the External Thermal Moisture Management System (ETMMS) approach warranted further evaluation as a roof-only approach for maximizing opportunities for insulation, air sealing, and roof deck ventilation. The second NorthernSTAR report, Airtightness Results of Roof-Only Air Sealing Strategies on 1 ½-Story Homes in Cold Climates (Ojczyk et al 2013b) investigated the airtightness impact of the roofonly, ETMMS technique on 1 ½-story homes.…”
Section: Executive Summarymentioning
confidence: 99%
See 1 more Smart Citation
“…Project Overcoat: An Exploration of Exterior Insulation Strategies for 1-1/2 Story Roof Applications in Cold Climates (Ojczyk et al 2013a) determined that the External Thermal Moisture Management System (ETMMS) approach warranted further evaluation as a roof-only approach for maximizing opportunities for insulation, air sealing, and roof deck ventilation. The second NorthernSTAR report, Airtightness Results of Roof-Only Air Sealing Strategies on 1 ½-Story Homes in Cold Climates (Ojczyk et al 2013b) investigated the airtightness impact of the roofonly, ETMMS technique on 1 ½-story homes.…”
Section: Executive Summarymentioning
confidence: 99%
“…This retrofit was completed in the fall of 2013 and no ice dams were reported during the winter of 2014. Ojczyk et al (2013b) provided supporting data on air exfiltration for roof overcoat projects using the ETMMS approach. Data from contractors using ETMMS to mitigate ice dams as well as supplemental data from Building America (BA) industry partners using an interior-only approach to improve energy efficiency shows a large variation in airtightness improvement in both the exterior-and interior-applied air sealing processes.…”
Section: Introductionmentioning
confidence: 99%
“…Industry Partners Ojczyk et al (2013b) discussed how several BA industry partners offered airtightness data from interior-applied, roof-only energy improvements to 1 ½-story homes participating in market-rate utility and weatherization programs. All three companies that provided air leakage data are BA industry partners and assist the NorthernSTAR BA partnership in research:…”
Section: Cost Review Of Interior-applied Air Sealing and Insulation Strategies Frommentioning
confidence: 99%
“…In Ojczyk et al (2013b), Cocoon provided testing results from two ETMMS roof-only projects located in Minnesota where the owners were seeking ice dam solutions. These projects represent successful realization of improved energy performance from measures motivated by ice dam mitigation.…”
Section: Interview With Steve Schirber Cocoonmentioning
confidence: 99%