Airflow and indoor air quality models of DOE prototype commercial buildings

Abstract: A previous report, NIST Technical Note 1734, Airflow and Indoor Air Quality Models of DOE Reference Commercial Buildings [1], detailed the CONTAM models of the 16 U. S. Department of Energy (DOE) reference commercial building models [2]. DOE developed the EnergyPlus building models for use in assessing new technologies and supporting the development of energy codes in pursuing building energy efficiency improvements. The DOE commercial reference buildings were developed to represent buildings that were constru… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
39
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(43 citation statements)
references
References 20 publications
0
39
0
Order By: Relevance
“…We used a multizone airflow and contaminant transport analysis modeling software, CONTAM 3.2 (NIST 2016), to predict concentrations resulting from gas and particle emissions from several combinations of desktop FFF 3D printers and filaments, assuming each printer is operated inside a one-story office building with a floor area of 511 square meters (m 2 ). The office building geometry and floor plan was taken from the Department of Energy Commercial Reference Building data set (Ng et al 2012). However, we modified some of the building characteristics in the CONTAM model to represent more realistic scenarios.…”
Section: Characteristics Of the Modeled Office Environmentmentioning
confidence: 99%
See 1 more Smart Citation
“…We used a multizone airflow and contaminant transport analysis modeling software, CONTAM 3.2 (NIST 2016), to predict concentrations resulting from gas and particle emissions from several combinations of desktop FFF 3D printers and filaments, assuming each printer is operated inside a one-story office building with a floor area of 511 square meters (m 2 ). The office building geometry and floor plan was taken from the Department of Energy Commercial Reference Building data set (Ng et al 2012). However, we modified some of the building characteristics in the CONTAM model to represent more realistic scenarios.…”
Section: Characteristics Of the Modeled Office Environmentmentioning
confidence: 99%
“…However, we modified some of the building characteristics in the CONTAM model to represent more realistic scenarios. Figure 1 shows the building floor plan divided into multiple zones and the maximum occupancy in each zone (Ng et al 2012).…”
Section: Characteristics Of the Modeled Office Environmentmentioning
confidence: 99%
“…2) Real buildings: The model of a health-care facility [39] is simulated, which consists of 126 zones (mainly examination, waiting and storage rooms) and 420 leakage paths consisting of doors and windows. Natural ventilation is assumed with the air flowing from 240 • relative to the north with a speed of 10 m/s.…”
Section: Performance Comparison Between Milp and Bphmentioning
confidence: 99%
“…Therefore, the combination of both can ensure predictable execution time as well as maintain the enforced constraints of the MILP. Under the on-line partitioning perspective, a hospital building [39] with 97 rooms comprised of 6 floors and 530 airflow leakages is analyzed. The building model includes 4 different air handling units systems that span all the building.…”
Section: On-line Partitioningmentioning
confidence: 99%
See 1 more Smart Citation