2017
DOI: 10.1016/j.jobe.2017.05.006
|View full text |Cite
|
Sign up to set email alerts
|

Air distribution system design optimization in non-residential buildings: Problem formulation and generation of test networks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
1
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(15 citation statements)
references
References 13 publications
0
1
0
Order By: Relevance
“…Sizing the ductwork is applied from the assumed variables and the estimated design flow rate in every section. Although the methods are straightforward, they hardly obtain a balanced design system [46]- [48]. Moreover, the resulting designs do not consider prevailing local economic conditions.…”
Section: Conventional Methods (Non-optimization)mentioning
confidence: 99%
See 2 more Smart Citations
“…Sizing the ductwork is applied from the assumed variables and the estimated design flow rate in every section. Although the methods are straightforward, they hardly obtain a balanced design system [46]- [48]. Moreover, the resulting designs do not consider prevailing local economic conditions.…”
Section: Conventional Methods (Non-optimization)mentioning
confidence: 99%
“…However, it is more likely to be trapped in a local optimum when dealing with more extensive test cases, e.g., conventional systems (further explained in the next paragraph). Recently, Jorens et al [6], [48], [68], [69] developed an air distribution network design (ADND) optimization algorithm, which focuses on optimizing the layout and sizes of the ductwork. For duct sizing, the method used a local search heuristic method, with a steepest-descent-mildest-ascent strategy as an optimization move strategy.…”
Section: Optimization Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Numerous papers have been dedicated to the design of air distribution systems or networks and several design (optimization) methods have been developed [3,4,5,6], e.g. the static regain method, equal friction method, T-method, … Jorens et al [7] give a critical review of the state-of-the-art in air distribution system design and identify two main shortcomings. First, previous methods only focus on the second phase of the design process, i.e., they only determine the size of each duct and/or fan in the system and consider the layout to be given.…”
Section: State Of the Artmentioning
confidence: 99%
“…Since humans spend 80-90% of their time indoors, it is vital to provide a healthy and comfortable environment in buildings [3]. Air handling and distribution systems aim to satisfy occupants by controlling indoor air quality (IAQ), temperature, and humidity [4].…”
Section: Introduction 1overviewmentioning
confidence: 99%