2019
DOI: 10.1007/978-3-030-27011-7_67
|View full text |Cite
|
Sign up to set email alerts
|

Air Distribution Efficiency in a Room by a Two-Flow Device

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
15
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
5
4

Relationship

4
5

Authors

Journals

citations
Cited by 20 publications
(15 citation statements)
references
References 6 publications
0
15
0
Order By: Relevance
“…In such conditions it is necessary to provide a sufficiently range of the flow. One of the means of increasing its range is the use of the Coanda effect, that is, the laying of a stream on the interior surfaces of walls or ceilings (Voznyak et al, 2019). In addition to increasing the range fertility, the phenomenon of laying a stream on the ceiling influences the flow of field, the expanded stream, the processes of mixing and extinction of velocity in the jet.…”
Section: Techniques Usedmentioning
confidence: 99%
“…In such conditions it is necessary to provide a sufficiently range of the flow. One of the means of increasing its range is the use of the Coanda effect, that is, the laying of a stream on the interior surfaces of walls or ceilings (Voznyak et al, 2019). In addition to increasing the range fertility, the phenomenon of laying a stream on the ceiling influences the flow of field, the expanded stream, the processes of mixing and extinction of velocity in the jet.…”
Section: Techniques Usedmentioning
confidence: 99%
“…The importance of providing normalized characteristics of the room microclimate due to low gabarites and presence of technological equipment as well maintenance personnel in the industrial premise on air velocity distribution and their features, is researched in (Gumen et al, 2016;Dovhaliuk & Міleikovskyi, 2007;Dovhaliuk & Mileikovskyi, 2008). It is known for example air distributors with a high intensity of the velocity and temperature extinguishing of the incoming air, that is, devices that provide an intense mixing of the tidal air with the environment (Dovhaliuk & Mileikovskyi, 2013;Voznyak et al, 2019). It is a great number of different designs of the air distribution devices and circuits of incoming air distribution, both in the upper and in the room serviced area, where the effect of the jets laying on the interior surfaces of walls or ceilings, which is a fairly wide spread phenomenon in ventilation technology (Voznyak et al, 2005).…”
Section: Techniques Usedmentioning
confidence: 99%
“…Comfort conditions at first are determined by the air velocity and internal temperature (Dovhaliuk & Міleikovskyi, 2007;Voznyak et al, 2005). These values are supported by ventilation devices and depend on the designed structure both of air exchange and air distribution schemes (Dovhaliuk & Міleikovskyi, 2008;Voznyak et al, 2019). Normalized characteristics of indoor air must be provided in the working area of industrial premises, since the fact that the sanitary-hygienic characteristics of the room microclimate of the industrial rooms correspond to the physiological needs of a person depends, to a large extent, on its health and efficiency (Dovhaliuk & Mileikovskyi, 2013;Voznyak et al, 2005).…”
Section: Introductionmentioning
confidence: 99%
“…Comfort conditions at first are determined by the air velocity and internal temperature (Dovhaliuk & Міleikovskyi, 2007;Voznyak et al, 2005). These values are supported by ventilation devices and depend on the designed structure both of air exchange and air distribution schemes (Dovhaliuk & Міleikovskyi, 2008;Voznyak et al, 2019). Normalized characteristics of indoor air must be provided in the working area of industrial premises, since the fact that the sanitary-hygienic characteristics of the room microclimate of the industrial rooms correspond to the physiological needs of a person depends, to a large extent, on its health and efficiency (Dovhaliuk & Міleikovskyi, 2013;Voznyak et al, 2005).…”
Section: Introductionmentioning
confidence: 99%