2021
DOI: 10.3389/fnut.2021.686513
|View full text |Cite
|
Sign up to set email alerts
|

Agreement of Single-Frequency Electrical Bioimpedance in the Evaluation of Fat Free Mass and Fat Mass in Peritoneal Dialysis Patients

Abstract: Background: Protein-energy wasting is related to impairment of quality of life and lower survival of end-stage kidney disease (ESKD) patients. The evaluation of body composition, especially fat free mass (FFM) and fat mass (FM), is important for the prediction of outcomes in these individuals. The aim of this study was to compare the FFM and FM measurements obtained by single-frequency bioimpedance (SF-BIA) and by a multiple frequency bioimpedance (MF-BIA) device, using dual energy X-ray absorptiometry (DXA) p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 26 publications
0
6
0
Order By: Relevance
“…However, a recent validation study showed that single‐frequency BIA had good correlation and agreement with dual‐energy X‐ray absorptiometry in patients on dialysis, which was more accurate than multifrequency BIA. 43 Fourth, in the stratification analysis, very few patients were classified in the poor ABI but normal VRI group because endothelial dysfunction usually develops in the early phase of atherosclerosis. 44 Also, there were some overlapped characteristics of vascular indices and endothelial biomarkers we measured ( Table S4 ).…”
Section: Discussionmentioning
confidence: 99%
“…However, a recent validation study showed that single‐frequency BIA had good correlation and agreement with dual‐energy X‐ray absorptiometry in patients on dialysis, which was more accurate than multifrequency BIA. 43 Fourth, in the stratification analysis, very few patients were classified in the poor ABI but normal VRI group because endothelial dysfunction usually develops in the early phase of atherosclerosis. 44 Also, there were some overlapped characteristics of vascular indices and endothelial biomarkers we measured ( Table S4 ).…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, the assessment of muscle and fat mass by BIS should have a theoretical advantage such that the measurements seemed to be less biased by hydration status. On the other hand, a recent study that compared BIS to DEXA suggested that difference (if any) in body composition measurement between these two modalities had a significant correlation with OH [ 31 ]; but this finding could not be replicated in another study with similar design [ 32 ]. To this end, it is important to recognize that the estimation of LBM by DEXA was in fact strongly influenced by hydration status [ 33 ].…”
Section: Discussionmentioning
confidence: 99%
“…Most of the studies demonstrated strong correlations (r > 0.7) between the parameters derived from bioimpedance techniques and those from DEXA in both PD and HD patients [ 48 , 49 , 50 , 51 , 52 , 53 ]. Konings et al were one of the first who compared the body composition parameters measured by MF-BIA and DEXA in 40 Caucasian PD patients [ 48 ].…”
Section: Principles and The Validation Of Bioimpedance In Eskdmentioning
confidence: 99%
“…These findings were confirmed in another study consisting of 50 PD patients, which again showed a good agreement in the FFM between BIS and DEXA. But BIS significantly overestimated FM by an average of 2.5 kg compared with DEXA, which became more pronounced in obese individuals [ 50 ].…”
Section: Principles and The Validation Of Bioimpedance In Eskdmentioning
confidence: 99%
See 1 more Smart Citation