2014
DOI: 10.1103/physreva.89.050501
|View full text |Cite
|
Sign up to set email alerts
|

Agreement between two88Sr+optical clocks to 4 parts in 1017

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

3
69
0
2

Year Published

2015
2015
2019
2019

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 90 publications
(74 citation statements)
references
References 28 publications
3
69
0
2
Order By: Relevance
“…For many operations in quantum information processing and metrology, these secular modes should ideally be prepared in their ground state. For example, in state-of-the-art trapped-ion optical clocks [7], uncertainty in the Doppler shift due to the residual excitation of these modes is a dominant contribution to the total clock uncertainty [8][9][10].All trapped-ion optical clocks to date have been operated with the ions' motion near the Doppler cooling limit [7][8][9][10]. For clocks based on quantum-logic spectroscopy of the 1 S 0 ↔ 3 P 0 transition in 27 Al + [11], the smallest uncertainty has been achieved by performing continuous sympathetic Doppler cooling on the logic ion ( 25 Mg + ) during the clock interrogation [8].…”
mentioning
confidence: 99%
“…For many operations in quantum information processing and metrology, these secular modes should ideally be prepared in their ground state. For example, in state-of-the-art trapped-ion optical clocks [7], uncertainty in the Doppler shift due to the residual excitation of these modes is a dominant contribution to the total clock uncertainty [8][9][10].All trapped-ion optical clocks to date have been operated with the ions' motion near the Doppler cooling limit [7][8][9][10]. For clocks based on quantum-logic spectroscopy of the 1 S 0 ↔ 3 P 0 transition in 27 Al + [11], the smallest uncertainty has been achieved by performing continuous sympathetic Doppler cooling on the logic ion ( 25 Mg + ) during the clock interrogation [8].…”
mentioning
confidence: 99%
“…with 88 Sr + [50] [51] and 171 Yb [52], thanks to the steady efforts of many laboratories worldwide in the field of optical frequency metrology.…”
Section: Fundamental Physics Testsmentioning
confidence: 99%
“…For many operations in quantum information processing and metrology, these secular modes should, ideally, be prepared in their ground state. For example, in state-of-the-art trappedion optical clocks [7], uncertainty in the Doppler shift due to the residual excitation of these modes is a dominant contribution to the total clock uncertainty [8][9][10].…”
mentioning
confidence: 99%
“…For many operations in quantum information processing and metrology, these secular modes should, ideally, be prepared in their ground state. For example, in state-of-the-art trappedion optical clocks [7], uncertainty in the Doppler shift due to the residual excitation of these modes is a dominant contribution to the total clock uncertainty [8][9][10].All trapped-ion optical clocks to date have been operated with the ions' motion near the Doppler cooling limit [7][8][9][10]. For clocks based on quantum-logic spectroscopy of the 1 S 0 ↔ 3 P 0 transition in 27 Al þ [11], the smallest uncertainty has been achieved by performing continuous sympathetic Doppler cooling on the logic ion ( 25 Mg þ ) during the clock interrogation [8].…”
mentioning
confidence: 99%
See 1 more Smart Citation