2020
DOI: 10.1038/s41372-020-0761-7
|View full text |Cite
|
Sign up to set email alerts
|

Agitated saline contrast to delineate central venous catheter position in neonates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
6
0
2

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(28 citation statements)
references
References 24 publications
0
6
0
2
Order By: Relevance
“…Foram 20 (62,5%) os artigos incluídos que abordaram o posicionamento do PICC no recém-nascido; onze (34,4%) apresentaram estratégias de posicionamento ideal do cateter por meio de USG e ecocardiografia, [26][27][34][35][36][37][38][39][40][41][42] um (3,1%) o USG em associação com infusão de solução salina agitada, 43 seis (18,8%) a eletrocardiografia intracavitária, 24,[44][45][46][47][48] e dois (6,3%) a radiografia. 16,49 Dos cateteres considerados bem-posicionados por meio de radiografia, 25% estavam em posição intracardíaca na avaliação por USG.…”
Section: Resultsunclassified
See 1 more Smart Citation
“…Foram 20 (62,5%) os artigos incluídos que abordaram o posicionamento do PICC no recém-nascido; onze (34,4%) apresentaram estratégias de posicionamento ideal do cateter por meio de USG e ecocardiografia, [26][27][34][35][36][37][38][39][40][41][42] um (3,1%) o USG em associação com infusão de solução salina agitada, 43 seis (18,8%) a eletrocardiografia intracavitária, 24,[44][45][46][47][48] e dois (6,3%) a radiografia. 16,49 Dos cateteres considerados bem-posicionados por meio de radiografia, 25% estavam em posição intracardíaca na avaliação por USG.…”
Section: Resultsunclassified
“…A estratégia mostrou-se promissora para melhorar a efetividade do posicionamento do PICC. 43 Seis artigos (18,8%) abordaram o uso do eletrocardiograma intracavitário (IC-ECG) como tecnologia no posicionamento do PICC. 24,[44][45][46][47][48] A ecocardiografia intracavitária verifica o posicionamento do PICC na veia cava por meio de alterações na onda P quando a ponta do cateter atinge a veia cava na junção atrial.…”
Section: Resultsunclassified
“…Agitated saline augmented echocardiography is used clinically to evaluate for intracardiac shunts. Recent studies have demonstrated the ability to confirm central venous catheter (CVC) line placement in neonates through visualization of agitated saline 7 . We were unable to find literature describing agitated saline augmented echocardiography to confirm IO line placement.…”
Section: Introductionmentioning
confidence: 99%
“…11 Furthermore, recent studies have also showed that intraprocedural tip location can be performed by trans-thoracic/subxiphoid ultrasound with 'bubble test'. [12][13][14] The 'bubble test' consists in the prompt visualization of the flow of a small amount of agitated saline solution inside the right heart sections, using transthoracic or subxiphoid ultrasound; a delayed or absent visualization of the 'bubbles' in the right atrium proves that the tip of the catheter is not located in the proximity of the cavo-atrial junction. The intraprocedural use of conventional IC-ECG, or of 'modified' IC-ECG for atrial fibrillation, and/or of ultrasound-based tip location have reduce to a minimum the need of intra-procedural fluoroscopy or post-procedural chest X-ray as radiological methods of tip location.…”
Section: Introductionmentioning
confidence: 99%