1992
DOI: 10.1109/61.127053
|View full text |Cite
|
Sign up to set email alerts
|

Aged ACSR conductors. II. Prediction of remaining life

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(9 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…The solar absorption factor directly influences the capacity of the overhead transmission line. The solar absorption factor has a direct impact on the heat gain rate (Qs), as described in (22). In contrast to conductor emissivity, solar absorption has the opposite impact on capacity.…”
Section: Impact Of Solar Absorption On the Ampacity Of Overhead Trans...mentioning
confidence: 99%
See 2 more Smart Citations
“…The solar absorption factor directly influences the capacity of the overhead transmission line. The solar absorption factor has a direct impact on the heat gain rate (Qs), as described in (22). In contrast to conductor emissivity, solar absorption has the opposite impact on capacity.…”
Section: Impact Of Solar Absorption On the Ampacity Of Overhead Trans...mentioning
confidence: 99%
“…Recent research on thermal stress along transmission lines has focused on the causes and effects of thermal stress as well as approaches to improve the reliability and optimize the performance of transmission lines [18,19]. To address the problem of thermal stress along transmission lines, different monitoring techniques have been developed on the basis of extensive studies [20,21] by evaluating thermal aging [22]. The reliability evaluation of transmission lines can be improved by better understanding the degradation mechanisms that cause component aging and failure [23].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Most of the original lines built in Central Iowa, the United States, in the 1940's and 1950's, have 3/0 ACSR, 6/1 conductors [1]. In Ontario, Canada, ACSR gained tremendous popularity in 1950s [2]. Since then, the study of operational behaviors on ACSR has begun its long journey.…”
Section: Introductionmentioning
confidence: 99%
“…Since then, the study of operational behaviors on ACSR has begun its long journey. The concern increases when most of these ACSR conductors have passed their 50-year design life, even though the predicted time for their service is limited to 60-70 years due to local contamination [2].…”
Section: Introductionmentioning
confidence: 99%