2024
DOI: 10.2463/mrms.mp.2022-0117
|View full text |Cite
|
Sign up to set email alerts
|

Age-related Decline of Intrinsic Cerebrospinal Fluid Outflow in Healthy Humans Detected with Non-contrast Spin-labeling MR Imaging

Abstract: Clearance of cerebrospinal fluid (CSF) is important for the removal of toxins from the brain, with implications for neurodegenerative diseases. Imaging evaluation of CSF outflow in humans has been limited, relying on venous or invasive intrathecal injections of contrast agents. The objective of this study was to introduce a novel spin-labeling MRI technique to detect and quantify the movement of endogenously tagged CSF, and then apply it to evaluate CSF outflow in normal humans of varying ages.Methods: This st… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
10
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(13 citation statements)
references
References 44 publications
1
10
0
Order By: Relevance
“…17 However, to improve the accuracy of signal increase ratio (SIR) curve fitting, the temporal resolution near inversion time (TI) = 1250 ms was increased since the preliminary scans showed it to be the TI where the peak flow occurs. 17 In a total, we collected 9 temporal points (9 TIs). Detailed methodology of time-resolved non-contrast MRI has been previously described by Malis et al 17 We used the simple subtraction of tag-off from the tag-on images to visualize intrinsic CSF moves out from the tagged region.…”
Section: Mr Protocolmentioning
confidence: 99%
See 3 more Smart Citations
“…17 However, to improve the accuracy of signal increase ratio (SIR) curve fitting, the temporal resolution near inversion time (TI) = 1250 ms was increased since the preliminary scans showed it to be the TI where the peak flow occurs. 17 In a total, we collected 9 temporal points (9 TIs). Detailed methodology of time-resolved non-contrast MRI has been previously described by Malis et al 17 We used the simple subtraction of tag-off from the tag-on images to visualize intrinsic CSF moves out from the tagged region.…”
Section: Mr Protocolmentioning
confidence: 99%
“…17 In a total, we collected 9 temporal points (9 TIs). Detailed methodology of time-resolved non-contrast MRI has been previously described by Malis et al 17 We used the simple subtraction of tag-off from the tag-on images to visualize intrinsic CSF moves out from the tagged region. To elucidate quantitative metrics of intrinsic CSF outflow, SIR was calculated using SIR = |Tag-on -Tag-off|/|Tag-off| to observe a perfusion-like function.…”
Section: Mr Protocolmentioning
confidence: 99%
See 2 more Smart Citations
“…These techniques measure fluid motion by modifying the MR signal corresponding to the amount of water movement. Typical techniques include spin labeling (SL), [12][13][14][15] phase contrast (PC), [16][17][18][19][20][21][22] and diffusion-weighting (DW). [23][24][25][26][27][28] SL detects signals from spins excited in specific regions and outflows from the regions after a certain delay.…”
Section: Introductionmentioning
confidence: 99%