Ag+ Interference from Ag/AgCl Wire Quasi-Reference Counter Electrode Inducing Corrosion Potential Shift in an Oil-Immersed Scanning Micropipette Contact Method Measurement

Abstract: Quantitative scanning micropipette contact method measurements are subject to the deleterious effects of reference electrode interference. The commonly used Ag/AgCl wire quasi-reference counter electrode in the miniaturized electrochemical cell of the scanning micropipette contact method was found to leak Ag+ into the electrolyte solution. The reduction of these Ag+ species at the working electrode surface generates a faradaic current, which significantly affects the low magnitude currents inherently measured … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
44
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 22 publications
(45 citation statements)
references
References 49 publications
(68 reference statements)
1
44
0
Order By: Relevance
“…The meniscus was additionally stabilized with a mineral oil layer. Oil is used to stabilize electrochemical cells on hydrophilic surfaces without their contamination, since oxide–water contact is thermodynamically more preferable than oxide–oil one, especially under UV radiation . The experimental test of mineral oil coating effect was described in Figure S15 in the Supporting Information.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The meniscus was additionally stabilized with a mineral oil layer. Oil is used to stabilize electrochemical cells on hydrophilic surfaces without their contamination, since oxide–water contact is thermodynamically more preferable than oxide–oil one, especially under UV radiation . The experimental test of mineral oil coating effect was described in Figure S15 in the Supporting Information.…”
Section: Resultsmentioning
confidence: 99%
“…The nanopipette was immediately withdrawn after contacting the sample surface to minimize surface moistening. For high-resolution imaging, the sample surface was additionally covered with the thin layer (<0.1 mm) of mineral oil (Nacalai) to prevent droplet spreading and decrease the signal noise. …”
Section: Methodsmentioning
confidence: 99%
“…Because of irregular mechanical motion, the output voltage ranges from 2 V to 25 V. According to these electrical signals, the gait can be capture and recognized. However, the electrical energy from TENG cannot directly power the electronics, which may cause micro electronic equipment overload and damage due to the overly high and irregular voltage [50][51][52]. In the future, the portable mobile gait monitor system will be integrated with more functions using a dedicated selfpowered ASIC.…”
Section: Resultsmentioning
confidence: 99%
“…23,24 This prevents the droplet from evaporating and spreading, which significantly increases the stability of the droplet electrochemical cell. 22,23,25 Taking advantage of OI-SECCM, this work explored the correlation between corrosion and grain orientations of Al alloy AA7075-T73. For Al, the presence of a passive oxide film reduces the conductivity and reactivity of the surface, 26,27 resulting in extremely low currents in microscopic electrochemical measurements.…”
Section: Introductionmentioning
confidence: 99%