Aerosol Particle Generation from Dry Powder Inhalers: Can They Equal Pressurized Metered Dose Inhalers?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
29
0
2

Year Published

1997
1997
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 69 publications
(31 citation statements)
references
References 4 publications
0
29
0
2
Order By: Relevance
“…Both in vitro and in vivo deposition studies show that delivered drug fractions in the required aerodynamic size fraction from early capsule-based DPIs with adhesive mixtures are quite low ( Figure 1) [55,56]. The carrier-free formulation from the Turbuhaler generally performs much better, even in comparison with MDIs that deliver the same drug [57,58]. The explanation for this poor performance of the early capsule-based DPIs is in the strong interparticulate forces in the adhesive mixtures and the absence of efficient dispersion principles in these inhalers.…”
Section: 'Repair Actions' For Design Weaknesses Of Early Dpi Conceptsmentioning
confidence: 99%
“…Both in vitro and in vivo deposition studies show that delivered drug fractions in the required aerodynamic size fraction from early capsule-based DPIs with adhesive mixtures are quite low ( Figure 1) [55,56]. The carrier-free formulation from the Turbuhaler generally performs much better, even in comparison with MDIs that deliver the same drug [57,58]. The explanation for this poor performance of the early capsule-based DPIs is in the strong interparticulate forces in the adhesive mixtures and the absence of efficient dispersion principles in these inhalers.…”
Section: 'Repair Actions' For Design Weaknesses Of Early Dpi Conceptsmentioning
confidence: 99%
“…Some show little variation with increasing flow rate whereas others show marked increases in inspirable particles with increasing flow rates. 12,[43][44][45][46][47] Forceful fast inhalations enhance the effect of many DPIs in children, whereas breath-holding, tilting of the head during inhalation or inhalation from functional residual capacity instead of residual volume do not seem to influence the clinical effect. 12 The inhalation effort and the inhalation flow rate required to generate the optimal therapeutic aerosol vary between different DPIs.…”
Section: Dry Powder Inhalersmentioning
confidence: 99%
“…An in vitro study comparing the proportion of the nominal dose of different corticosteroids delivered as fine drug particles from four different DPIs at different flow rates showed that the Turbuhaler device produced a higher proportion of respirable particles than the other devices, and this was consistent across the range of applied inspiratory force [12]. These in vitro findings need to be confirmed with in vivo deposition studies.…”
Section: Comparing Devices For Chronic Obstructive Pulmonary Diseasesmentioning
confidence: 91%
“…Due to the large amount of small particles and the moderate inbuilt resistance in Turbuhaler, which opens up the vocal cords during inhalation, Turbuhaler is associated with higher lung deposition (25e40% of the delivered dose) compared with pMDIs and other DPIs [12,16]. A good correlation has been found between lung deposition and clinical efficacy.…”
Section: Comparing Devices For Chronic Obstructive Pulmonary Diseasesmentioning
confidence: 99%