2004
DOI: 10.1088/0031-9155/49/4/r01
|View full text |Cite
|
Sign up to set email alerts
|

Advances in the determination of absorbed dose to water in clinical high-energy photon and electron beams using ionization chambers

Abstract: During the last two decades, absorbed dose to water in clinical photon and electron beams was determined using dosimetry protocols and codes of practice based on radiation metrology standards of air kerma. It is now recommended that clinical reference dosimetry be based on standards of absorbed dose to water. Newer protocols for the dosimetry of radiotherapy beams, based on the use of an ionization chamber calibrated in terms of absorbed dose to water, N(D,w), in a standards laboratory's reference quality beam… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
18
0
2

Year Published

2005
2005
2018
2018

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 30 publications
(22 citation statements)
references
References 106 publications
(189 reference statements)
2
18
0
2
Order By: Relevance
“…This fact has also been noted by other authors (Bjerke H. and Hult A., 2004) and (Huq M. and Andreo P., 2004).…”
Section: Calibration Coefficient In Terms Of Air (N K )supporting
confidence: 86%
“…This fact has also been noted by other authors (Bjerke H. and Hult A., 2004) and (Huq M. and Andreo P., 2004).…”
Section: Calibration Coefficient In Terms Of Air (N K )supporting
confidence: 86%
“…A priori , one of these improvements is a reduction in the uncertainty during determination of the absorbed dose to water. However, a recent publication, (7) which is also analyzed in the present work, has questioned this argument.…”
Section: Introductionmentioning
confidence: 57%
“…The uncertainty value provided by Ciemat in NK for the NE 2571 chamber is 0.45%. The remaining parameters that enter into the determination of ND,air and of the components associated with the perturbation factors in the user beam pQ, and to the water–air stopping power ratio sw,air, were taken from Huq and Andreo (7) . Thus the uncertainty in ND,air can be set for a cylindrical chamber at 0.8%.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Em Radioterapia, a dose é verificada através de métodos protocolados de controle da qualidade e do uso de dispositivos, os chamados dosímetros, com características adequadas, entre elas sensibilidade, reprodutibilidade e repetitividade e baixo desvanecimento do sinal dosimétrico (HUQ et al, 2004). Alguns dos dosímetros mais utilizados na prática clínica são as câmaras de ionização, utilizada como dosímetro de referência por protocolos internacionais (HUQ et al, 2004;HSU et al, 2010), os filmes e os dosímetros termoluminescentes (TL).…”
Section: Dosimetria Oslunclassified