Proceedings of the 10th International Congress for Applied Mineralogy (ICAM) 2012
DOI: 10.1007/978-3-642-27682-8_45
|View full text |Cite
|
Sign up to set email alerts
|

Advances in Quantitative X-Ray Mineralogy: Mixed Crystals in Bauxite

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
1

Year Published

2013
2013
2021
2021

Publication Types

Select...
5
1
1

Relationship

3
4

Authors

Journals

citations
Cited by 10 publications
(11 citation statements)
references
References 7 publications
0
10
1
Order By: Relevance
“…Quantitative analyzes were performed by refinement of the total multiphase spectrum method, known as the Rietveld method [11][12][13], with Bruker-AXS Diffrac.Topas 5.0 software. The crystal structure files of the phases were sourced from the Bruker-AXS and COD (Crystallographic Open Database) databases, with implementation for the restricted refinement of isomorphic substitutions in goethite [12][13][14], hematite [13][14][15] and the solid solution magnetite-maghemite [3].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Quantitative analyzes were performed by refinement of the total multiphase spectrum method, known as the Rietveld method [11][12][13], with Bruker-AXS Diffrac.Topas 5.0 software. The crystal structure files of the phases were sourced from the Bruker-AXS and COD (Crystallographic Open Database) databases, with implementation for the restricted refinement of isomorphic substitutions in goethite [12][13][14], hematite [13][14][15] and the solid solution magnetite-maghemite [3].…”
Section: Methodsmentioning
confidence: 99%
“…The polished blocks were analyzed on reflected light microscope (Zeiss Axioimager M2.m) and Raman microprobe. A Horiba Jobin-Yvon LabRam 800HR spectrometer coupled to an Olympus BX-41 polarizing microscope was employed, using a 632.8 nm excitation laser with neutral density filters to reduce the laser power to 0.7 mW in order to avoid oxidation [14][15][16]. Even reducing the laser power, the spectra had to be measured quickly, for three accumulations of 2 s each, since the decrease in the intensity of the maghemite diagnostic vibrations was observed for longer measurement times.…”
Section: Methodsmentioning
confidence: 99%
“…The results are fast and reliable. 24 The elemental chemical composition was determined by X-ray fluorescence (Shimadzu XRF 800HS). Calibration curves (0.1-1000 mg kg −1 ) for fluorine, aluminum, sodium, silicon, iron, calcium, potassium, magnesium and zirconium were employed for the quantitative analyses of these elements.…”
Section: Characterization Of Ore Samplesmentioning
confidence: 99%
“…The low content in silicates, however, tends to increase the uncertainties related to the quantification by the XRD/Rietveld method. 24 Elemental analysis of fluorine in fluorine-rich minerals by XRF appears thus to be possible.…”
Section: Characterization Of the Ore Samplesmentioning
confidence: 99%
“…The procedure was elegantly included in the Rietveld refinement procedure by Knorr andNeumann (2011) andNeumann et al (2014).…”
Section: Lattice Constant Refinement For the Evaluation Of Hematite Amentioning
confidence: 99%