Advancements in accuracy of the alanine dosimetry system. Part 2. The influence of the irradiation temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

9
29
0

Year Published

2005
2005
2019
2019

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 62 publications
(38 citation statements)
references
References 12 publications
9
29
0
Order By: Relevance
“…By contrast, calibration with alanine against the national standard sources requires only two corrections: one for 60 Co decay with a precisely known half-life of 1925.23 days (Nagy, Puhl, et al 2000) and another for differences between the mass energy absorption coefficients for water and soft tissue, which is small (<1%) and reasonably well-known (Woods, et al 2004). …”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…By contrast, calibration with alanine against the national standard sources requires only two corrections: one for 60 Co decay with a precisely known half-life of 1925.23 days (Nagy, Puhl, et al 2000) and another for differences between the mass energy absorption coefficients for water and soft tissue, which is small (<1%) and reasonably well-known (Woods, et al 2004). …”
Section: Discussionmentioning
confidence: 99%
“…Prior to use, the pellets were stored in a desiccator over phosphorus pentoxide, which provided 0% relative humidity . The pellets were conditioned to the humidity of the ambient environment before use (Nagy, Puhl, et al 2000) and were irradiated in the phantoms in plastic vials purchased from NIST (figure 4). The vial height was approximately 30 mm; the outer diameter was 12 mm, while the inner diameter allowed 0.2 mm of space for the 4.9 mm diameter of the pellets (Nagy and Desrosiers, 1996).…”
Section: Dosimetrymentioning
confidence: 99%
See 1 more Smart Citation
“…All the dosimeters returned from the NPP were stored under stable conditions in darkness (temperature: 21~26ºC, relative humidity: 16~ 22%). For determination of the absorbed dose of alanine dosimeters, measurements were performed at least eight times on a daily basis after two or three weeks and data was corrected by the factor of the dosimeter mass and the irradiation temperature in the NPP (0.14%/K, 25ºC) [12]. To accurately measure the peak to peak ratio ("x/y ratio" or No 7 over No 8 ratio in Fig.…”
Section: Dosimeter Installation and Measurementmentioning
confidence: 99%
“…This molecule can therefore be considered a model system for more complex molecules, such as DNA constituents, because it has a carbon backbone as well as carboxyl and amino groups. Alanine also is important for radiation dosimetry as it is used as a secondary standard in high dose dosimetry [44][45][46]. In the solid state, L-α-alanine generates stable radicals which are suitable for use in electron paramagnetic resonance (EPR) dosimetry [47].…”
Section: Introductionmentioning
confidence: 99%