2000
DOI: 10.1109/59.852111
|View full text |Cite
|
Sign up to set email alerts
|

Advanced SVC models for Newton-Raphson load flow and Newton optimal power flow studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
78
0
1

Year Published

2011
2011
2020
2020

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 224 publications
(79 citation statements)
references
References 7 publications
0
78
0
1
Order By: Relevance
“…From Figure 5, it is easy to see that there are a lot of buses that violate the lower voltage limit, namely, 8,14,17,35,36,43,47 and 48, which present that more than 13% of the system buses have a voltage collapse. Hence, the most voltage deviation is marked in bus 36 with 0.168 pu, which makes it the most suitable placement for the STATCOM device.…”
Section: Case 1: One Statcom Onlymentioning
confidence: 99%
See 1 more Smart Citation
“…From Figure 5, it is easy to see that there are a lot of buses that violate the lower voltage limit, namely, 8,14,17,35,36,43,47 and 48, which present that more than 13% of the system buses have a voltage collapse. Hence, the most voltage deviation is marked in bus 36 with 0.168 pu, which makes it the most suitable placement for the STATCOM device.…”
Section: Case 1: One Statcom Onlymentioning
confidence: 99%
“…Furthermore, the state variables describing FACTS devices and those describing the power network are combined in one single frame of reference to get a unified, iterative solution through the Newton-Raphson method [8][9][10]. The aforementioned approach mingles the alternating current (AC) network and power system controller state variables in a single system of simultaneous equations…”
Section: Building Of Jacobian Matrix Including Facts Controllersmentioning
confidence: 99%
“…The following equation gives the procedure to obtain n set of data generated from PSO. (12) From the above generated data, the minimum cost function is taken as the power generated by the generator with low cost.…”
Section: Updating Initial Particlesmentioning
confidence: 99%
“…OPF method has been successfully used to determine the FACTS parameters to control the power flow in the specific lines [7]. Ambriz-Perez et al [8] have solved OPF problem incorporating FACTS devices using Newton's method, leading to highly robust iterative solutions. Chung and Li [9] have presented GA to determine the parameters of FACTS devices.…”
Section: Introductionmentioning
confidence: 99%