2021
DOI: 10.1109/jxcdc.2021.3130041
|View full text |Cite
|
Sign up to set email alerts
|

Advanced SiGe:C HBTs at Cryogenic Temperatures and Their Compact Modeling With Temperature Scaling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 25 publications
(35 reference statements)
2
3
0
Order By: Relevance
“…For Φ BI (CV ), the error bars represent the 2-σ error in Φ BI , obtained by performing fits with (2) for 100 C BE − V BE sweeps with errors randomly determined based on a normal distribution defined by the uncertainty in the measured C BE . The extracted Φ BI (CV ) is observed to weakly increase with decreasing temperature, consistent with observations for similar devices [10] and Schottky diodes [17]. In contrast, Φ BI (IV ) exhibits a stronger dependence on temperature, as observed previously for Schottky diodes [11,17], and differs markedly in magnitude from the Φ BI (CV ).…”
Section: Resultssupporting
confidence: 88%
See 3 more Smart Citations
“…For Φ BI (CV ), the error bars represent the 2-σ error in Φ BI , obtained by performing fits with (2) for 100 C BE − V BE sweeps with errors randomly determined based on a normal distribution defined by the uncertainty in the measured C BE . The extracted Φ BI (CV ) is observed to weakly increase with decreasing temperature, consistent with observations for similar devices [10] and Schottky diodes [17]. In contrast, Φ BI (IV ) exhibits a stronger dependence on temperature, as observed previously for Schottky diodes [11,17], and differs markedly in magnitude from the Φ BI (CV ).…”
Section: Resultssupporting
confidence: 88%
“…II, these data are analyzed to obtain Φ BI from the I C − V BE and C BE − V BE characteristics. At room temperature, Φ BI (CV ) is found to be 0.83 V, in good agreement with [10]. This value is specified as the room temperature value for Φ BI (IV ) to facilitate comparison at other temperatures.…”
Section: Resultssupporting
confidence: 56%
See 2 more Smart Citations
“…The small-signal circuit parameters are calibrated using the extracted and measured device characteristics given in [7] and [19] in order to examine the behavior of the LNA at CT. In essence, we found the scale factors of the parameters when the operating temperature decreased from 300 to 4 K RT to CT. We then adjusted the room temperature small-signal parameters by applying these scale factors while taking the transistor sizes into consideration, and the altered circuit parameters are presented in Table II.…”
mentioning
confidence: 99%