Abstract: Technological evolution has allowed impedance analysis to become a versatile and efficient method for the precise measurement of the equivalent electrical parameters of the quartz crystal microbalance (QCM). By measuring the dissipation factor, or another equivalent electrical parameter, the QCM sensor provides access to the sample mass per unit area and its physical parameters, thus ensuring a detailed analysis. This paper aims to demonstrate the benefits of advanced impedance spectroscopy concerning the Butt… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
3

Relationship

2
4

Authors

Journals

citations
Cited by 13 publications
(31 citation statements)
references
References 35 publications
(43 reference statements)
0
27
0
Order By: Relevance
“…One of the two arms is called static and contains only a capacitance determined by the existence of QCM sensor electrodes. The second arm models the piezoelectric properties of the QCM sensor [ 34 ]. This arm consists of two complex conjugated circuit elements that model the energy storage process, and a third element that models the dissipative processes of the QCM sensor.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…One of the two arms is called static and contains only a capacitance determined by the existence of QCM sensor electrodes. The second arm models the piezoelectric properties of the QCM sensor [ 34 ]. This arm consists of two complex conjugated circuit elements that model the energy storage process, and a third element that models the dissipative processes of the QCM sensor.…”
Section: Methodsmentioning
confidence: 99%
“…If the scanning range is wrong, based on phase information, a new set of the frequency start and frequency stop is updated and the impedance measurement is reloaded. By applying the methods described in the literature [ 31 , 34 ], the electrical elements parameters of the BVD model are determined. The value of the motional capacitance is retained in this stage and it can be expressed in the form: where, and are directly correlated with the maximum and minimum of the raw data measured using VIA.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The Analog Discovery 2 (AD2) virtual instrument from Digilent Inc., Pullman, WA, USA [27] has been successfully used in various applications [28][29][30]. The WaveForms device manager provides alternate FPGA configuration files with different resource allocations.…”
Section: Regenerative Ring-down Qcmmentioning
confidence: 99%
“…The BVD parameters for polyvinyl alcohol (PVA) coated QCM sensor was obtained using a virtual impedance analyzer (VIA) already presented in the literature [28,30]. In Figure 5a, the VIA results for the QCM sensor are shown.…”
Section: Natural Ring-down Of the Qcm Sensormentioning