2023
DOI: 10.1109/tim.2023.3315402
|View full text |Cite
|
Sign up to set email alerts
|

Advanced Dual-Probes Noncontact Voltage Measurement Approach for AC/DC Power Transmission Wire Based on the Electric Field Radiation Principle

Yankai Xing,
Jinpu Liu,
Fuchao Li
et al.
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
0
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 22 publications
0
0
0
Order By: Relevance
“…To have a smart grid, it is necessary to monitor the grid voltage, and given the changes in the loads of the current electricity system, the continuous monitoring of this voltage is necessary. The correct management of these measures requires cyber-physical systems (CPS) made up of computer systems for data processing, communication networks, and sensors that allow interaction with the physical world and the virtual or computer world [1].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…To have a smart grid, it is necessary to monitor the grid voltage, and given the changes in the loads of the current electricity system, the continuous monitoring of this voltage is necessary. The correct management of these measures requires cyber-physical systems (CPS) made up of computer systems for data processing, communication networks, and sensors that allow interaction with the physical world and the virtual or computer world [1].…”
Section: Introductionmentioning
confidence: 99%
“…In the classification of analogue isolated high-voltage probes, two types can be distinguished according to the location of the isolation: those using a non-intrusive sensor/measuring coupling system [1,2] and those using an intrusive one [3,4], that connect a circuit to the system and then use a coupling method, either optical, capacitive, inductive, or through the power supply, to achieve the isolation. In [1], the authors present a nonintrusive probe for the non-contact measurement of voltages of 10 kV and a bandwidth of 4.5 MHz, based on the electric field coupling principle using the dual-pin-type probe method. Also based on non-intrusive capacitive coupling, the development of a probe for voltage measurements up to 1000 V, for the direct proportional measurement of the true RMS value containing a 50-60 Hz waveform with a cut-off frequency of 6 kHz, is presented in [2].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation