2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability 2007
DOI: 10.1109/irep.2007.4410560
|View full text |Cite
|
Sign up to set email alerts
|

Advanced distance protection applications fot dynamic loading and out-of step condition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…It's considered the main protection for OHTL. The development in the protection relays from electromechanical relay and solid-state relays with mho quadrature to Intelligent Electronic Device (IEDs), numerical relay is the important factor in the widespread acceptance of this type of protection functions at different voltage levels all over the world [11] . The first zone in distance function protection is used to provide primary high-speed protection which operates instantaneous, to a significant portion of the transmission line.…”
Section: Distance Protection Performancementioning
confidence: 99%
See 2 more Smart Citations
“…It's considered the main protection for OHTL. The development in the protection relays from electromechanical relay and solid-state relays with mho quadrature to Intelligent Electronic Device (IEDs), numerical relay is the important factor in the widespread acceptance of this type of protection functions at different voltage levels all over the world [11] . The first zone in distance function protection is used to provide primary high-speed protection which operates instantaneous, to a significant portion of the transmission line.…”
Section: Distance Protection Performancementioning
confidence: 99%
“…The first zone in distance function protection is used to provide primary high-speed protection which operates instantaneous, to a significant portion of the transmission line. The second zone is used to cover the rest of the protected line and provide some backup for the remote end bus [10,11] . The third zone is the backup protection for the first and second zone for all the lines connected to the remote end bus.…”
Section: Distance Protection Performancementioning
confidence: 99%
See 1 more Smart Citation
“…One aspect of online management is fault identification, diagnostics, prognostication, and mitigation. Inability to automatically and timely diagnose and pinpoint the source(s) of failures combined with the potential side-effects of automated protection actions lead to impending fault cascades, which can be avoided (Zhang, Ilic, & Tonguz, 2011;Tholomier, Richards, & Apostolov, 2007). Recent blackouts and hurricane Sandy in 2012 demonstrated the grid vulnerability and reasons to look at existing defense mechanism more closely.…”
Section: Introductionmentioning
confidence: 99%