2004
DOI: 10.1107/s090904950402878x
|View full text |Cite
|
Sign up to set email alerts
|

Advanced detection systems for X-ray fluorescence excitation spectroscopy

Abstract: This paper accounts for selected detector developments carried out over the past 15 years within the ESRF X-ray Absorption Spectroscopy group. This includes various types of photodiodes used as integrated current detectors. Special emphasis is put on the long-standing development of a Si drift-diode array suitable for energy-dispersive detection of X-ray fluorescence. This detector, which is now operational, was used to record high-quality XMCD/XAFS spectra on [Fe70Pt30] nanoparticles highly dispersed on a Si … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
23
0

Year Published

2006
2006
2013
2013

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(23 citation statements)
references
References 47 publications
(53 reference statements)
0
23
0
Order By: Relevance
“…The dashed line corresponds to envisioned minimal upgrades to the JFET (see below), resulting in E thr = 200 eV. The dash-dotted line illustrates the ultimate performance (E thr ∼ 100 eV) that can be expected with present-day JFET technology, matching the state-of-the-art in low-noise x-ray detectors [21,24]. The combined effect of threshold and energy resolution can then be folded into the expected differential recoil rate in a reactor experiment (main plot, Fig.…”
Section: Figmentioning
confidence: 99%
“…The dashed line corresponds to envisioned minimal upgrades to the JFET (see below), resulting in E thr = 200 eV. The dash-dotted line illustrates the ultimate performance (E thr ∼ 100 eV) that can be expected with present-day JFET technology, matching the state-of-the-art in low-noise x-ray detectors [21,24]. The combined effect of threshold and energy resolution can then be folded into the expected differential recoil rate in a reactor experiment (main plot, Fig.…”
Section: Figmentioning
confidence: 99%
“…2 a typical display of the vector Spectrum Analyzer (VSA: Agilent Technologies Inc. 89600-SU) operated in the time-averaged mode using a synchronous low frequency triggering reference (F tg = F m /q). In this experiment, the X-ray fluorescence detector was a large area X-ray photodiode associated with a home-made preamplifier/readout electronics [31]. It clearly appears from Fig.…”
Section: Detection Constraints For Sub-thz Xdmrmentioning
confidence: 99%
“…This separation has long been symbolized by the existence of separate triannual international conference series on Vacuum Ultraviolet Radiation Physics 1) and X-ray Physics and Inner Shell Ionization. 2) The utility of hard XAS as a probe of chemical identity in the biological, environmental, and biomedical sciences is well documented [15][16][17][18][19][20][21]. Metals in enzymes can be probed in all oxidation states and spin states, and environmental samples can be examined in a chemically undisturbed form.…”
Section: Soft X-ray Absorption Edgesmentioning
confidence: 99%