2000
DOI: 10.1016/s0967-0661(99)00198-7
|View full text |Cite
|
Sign up to set email alerts
|

Advanced controller auto-tuning and its application in HVAC systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
52
0
1

Year Published

2012
2012
2018
2018

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 129 publications
(53 citation statements)
references
References 6 publications
0
52
0
1
Order By: Relevance
“…with simple on/off hysteresis based control, PI/PID control, or more advanced model based control. In most cases one of the first two methods is used [1], [2], [3], [4], primarily due to their simple implementations and relatively simple tuning procedures. Fig.…”
Section: Office Building Temperature Controlmentioning
confidence: 99%
See 1 more Smart Citation
“…with simple on/off hysteresis based control, PI/PID control, or more advanced model based control. In most cases one of the first two methods is used [1], [2], [3], [4], primarily due to their simple implementations and relatively simple tuning procedures. Fig.…”
Section: Office Building Temperature Controlmentioning
confidence: 99%
“…The temperature is often controlled with a heating ventilation and air-conditioning (HVAC) system using either on/off type hysteresis control or variations of PI/PID control due to their simple implementations [1], [2]. However, they seldom perform well at all possible operating conditions because the control is typically tuned only for a selected nominal situation; also the control might not be tuned properly in the first place [2], [3], [4].…”
Section: Introductionmentioning
confidence: 99%
“…To evaluate the effectiveness of the proposed AIFPI controller, its control performance is compared with a fixed well-tuned PI controller, which adopts the PI/PID tuning rules proposed by Wang [13]. It has been proved that the auto-tuning controller using the PI/PID tuning rules has good performance for HVAC systems [14]. Their behavior is all evaluated with MATLAB/Simulink simulation using the HVAC system model described by Eq.…”
Section: Application Of the Aifpi Controller To The Hvac Systemmentioning
confidence: 99%
“…These parameters are compared with ZeiglerNichols tuned parameters and model based gain scheduling is additionally employed to cope with the operating point dependent system gain. In [6], auto-tuners for PI/PID control of HVAC systems are designed based on a combination of relay and step tests. The auto-tuners show better performance than manual tuning and standard relay auto-tuning.…”
Section: Introductionmentioning
confidence: 99%