2014
DOI: 10.2478/jee-2014-0018
|View full text |Cite
|
Sign up to set email alerts
|

Advanced Control Strategy for Single–Phase Voltage–Source Active Rectifier with Low Harmonic Emission

Abstract: This paper introduces the advanced control of single-phase voltage-source active rectifier. This control provide direct control of trolley-wire current and active damping of low-frequency disturbances at the converter ac side. Our proposed control strategy combines PR controller with feed-forward model and low-frequency harmonic compensator based on resonant controllers. Achieved experimental results show excellent converter behavior, where converter is fed by strongly distorted supply voltage.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
4
3

Relationship

3
4

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…This paper presented single-phase voltage synchronization based on SOGI-PLL structure. This type of voltage synchronization is very good solution for traction active rectifier, for example [11] - [13]. This synchronization is also suitable for use in advanced PV power station of low-power or for special single-phase power supply source [14] - [15].…”
Section: Conslusionsmentioning
confidence: 93%
“…This paper presented single-phase voltage synchronization based on SOGI-PLL structure. This type of voltage synchronization is very good solution for traction active rectifier, for example [11] - [13]. This synchronization is also suitable for use in advanced PV power station of low-power or for special single-phase power supply source [14] - [15].…”
Section: Conslusionsmentioning
confidence: 93%
“…The direct current control is provide by PR controller and resonant controllers are used for harmonic compensation (for dead-time effect minimization). This method is well described in [16]. The voltage balancing is important during fast transient and is possible used some of these method [11], [17], [18].…”
Section: Proposed Control Of Multilevel Convertermentioning
confidence: 99%
“…This resonant controller (R3rd) is in this case use as third harmonic compensator (for dead-time effect minimization). This method is well described in [10] or it is also possible to use filtration method described in [12] and [13]. The resulting value uv_m1_a enters into PWM modulator and firing pulses switch the first cell (H-bridge) of phase_a.…”
Section: Proposed Controlmentioning
confidence: 99%
“…These requirements are difficult to achieve especially for non-symmetrical condition like two phase operation for single-phase ac grid ground short-circuit. In addition we want to ensure a very low current ripple therefore PS-PWM (phase shifted pulse-width modulation) is used with zero vector alternating, which is well described in [10]- [11].…”
Section: Introductionmentioning
confidence: 99%