2005
DOI: 10.1016/j.elecom.2005.08.022
|View full text |Cite
|
Sign up to set email alerts
|

Adsorptive stripping voltammetry of nickel and cobalt at in situ plated lead film electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
65
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 101 publications
(66 citation statements)
references
References 17 publications
1
65
0
Order By: Relevance
“…The only example of simultaneous determination of nickel and cobalt was reported by Korolczuk et al using an in situ prepared lead film electrode (PbFE) [34], but lead is also a toxic element.…”
Section: Introductionmentioning
confidence: 99%
“…The only example of simultaneous determination of nickel and cobalt was reported by Korolczuk et al using an in situ prepared lead film electrode (PbFE) [34], but lead is also a toxic element.…”
Section: Introductionmentioning
confidence: 99%
“…The GCE modifiers in common use are metals (mercury , gold [81][82][83][84][85], cadmium [87], copper [88], lead [89], platinum [90], bismuth [91][92][93][94][95][96]) and facilitating the precipitation of amalgam-forming and electropositive elements. Organic substances (OS) [107][108][109][110][111][112][113][114][115][116][117][118][119][120][121], macrocyclic compounds [122][123][124][125][126], polymers [127-131, 157-159, 165-166, 169-175], bioactive compounds [186], and nanotubes [187][188][189][190] can also serve as GCE modifiers.…”
Section: Glassy-carbon Electrodesmentioning
confidence: 99%
“…6) . This was probably attributed to the In situ plated lead film glassy carbon electrode SW-AdCSV DMG 1-100 nM 280 pM (t acc = 120 s) [28] In situ plated lead film glassy carbon electrode CC-CAdSCP DMG 0.75-8 nM 0.4 nM (t acc = 210 s) [9] In situ plated lead film screen-printed electrode SW-AdCSV DMG 50-500 nM 5 nM (t acc = 90 s) [27] In situ lead film carbon screen-printed electrode SW-AdCSV Nioxime 0.5-210 nM 50 pM (t acc = 120 s) [29] In situ plated lead-copper film electrode DMG dimethylglyoxime, SW-AdCSV square wave adsorptive cathodic stripping voltammetry, DP-AdCSV differential pulse adsorptive cathodic stripping voltammetry, CC-CAdSCP catalytic adsorptive stripping chronopotentiometric Fig. 6 Effect of possible interfering species on the Co 2+ determination at the SnBiE.…”
Section: Study Of Interferencesmentioning
confidence: 99%
“…The detection limit was given by the equation C L = 3S bl /S, where S bl is the standard deviation of the blank measurements and S is the sensitivity of the calibration graph. The detection limit of Co 2+ for 60 s accumulation was calculated to be 44 pM, which is lower than that at hanging mercury drop electrode [2,16], stationary mercury drop electrode [37], cylindrical silver-based renewable amalgam film electrode [13,38], in situ and ex situ plated bismuth film electrode [39][40][41][42], solid bismuth disk vibrating electrode [43], in situ plated lead film glassy carbon electrode and screen-printed electrode [9,27,28], and in situ plated leadcopper film electrode [30]. The data for the application of various electrodes in the AdCSV determination of Co 2+ is show in Table 2.…”
Section: Calibration Curvementioning
confidence: 99%
See 1 more Smart Citation