2001
DOI: 10.1002/1521-4125(200110)24:10<1001::aid-ceat1001>3.0.co;2-o
|View full text |Cite
|
Sign up to set email alerts
|

Adsorption Measurement of Water/Ethanol Mixtures on Activated Carbon Fiber

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2006
2006
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 5 publications
0
4
0
Order By: Relevance
“…Subtracting out the gas-phase contribution from the total hydrogen loading data in Figure enables one to establish a hydrogen isotherm. In Figure , isotherm data from the capsule unit based on the experimental data shown in Figure are compared to literature data for the H 2 −GX31 system measured by a traditional gravimetric sorption technique , and a differential pressure adsorption unit (DPAU) . In addition, data are included for a second, completely independent, capsule investigation using a 1.6787 g sample.…”
Section: Resultsmentioning
confidence: 99%
“…Subtracting out the gas-phase contribution from the total hydrogen loading data in Figure enables one to establish a hydrogen isotherm. In Figure , isotherm data from the capsule unit based on the experimental data shown in Figure are compared to literature data for the H 2 −GX31 system measured by a traditional gravimetric sorption technique , and a differential pressure adsorption unit (DPAU) . In addition, data are included for a second, completely independent, capsule investigation using a 1.6787 g sample.…”
Section: Resultsmentioning
confidence: 99%
“…The CO 2 adsorption isotherms in the absence of water vapor were measured at 313 K on a ChemiSorb HTP chemical adsorption analyzer (Micromeritics, Japan) after pretreatment of the adsorbent material under a He flow at 343 K for 6 h. In contrast, the CO 2 adsorption isotherms in the presence of water vapor (moisture pre-adsorption) at 313 K were obtained on BELSORP-BG (BEL Japan, Inc.) after pretreatment of the adsorbent material at 343 K for 6 h under vacuum. Measurements obtained on BELSORP-BG are based on a gravimetric–volumetric method for determination of the binary component gaseous adsorption isotherms. …”
Section: Methodsmentioning
confidence: 99%
“…In the present study, we have explored some effects of water vapor on the chemo-resistive behavior of a set of different vQRS, exposed to different types of VOC having different polarities and present in exhaled breath. Water molecules can interact with analytes before impacting the transducer but also compete with them upon adsorption in the conductive polymer nanocomposite (CPC) layer and during their diffusion to the nano-junctions of the conducting architecture [48][49][50][51][52]. Polar VOC can be soluble in water at different degrees and sometimes can create hydrogen bondings [53][54][55].…”
Section: Name Pvp Aps Appmentioning
confidence: 99%