1993
DOI: 10.1021/ac00062a019
|View full text |Cite
|
Sign up to set email alerts
|

Adsorption, immobilization, and hybridization of DNA studied by the use of quartz crystal oscillators

Abstract: Quartz crystal oscillators have been used as microbalances, the so-called quartz crystal microbalance, because their resonant frequencies change by mass loading onto the surface

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
57
0
2

Year Published

1996
1996
2016
2016

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 140 publications
(59 citation statements)
references
References 5 publications
0
57
0
2
Order By: Relevance
“…The parallel resonant frequency depends not only on the quartz crystal but also on the associated circuit and all capacitances in parallel with the device (eq. [14], Table 3). The measurement o f f , can be very useful in determining specific properties of the h o u n d i n g media such as in the case of electrolytes (26).…”
Section: Conductivity (D'nil)mentioning
confidence: 99%
See 1 more Smart Citation
“…The parallel resonant frequency depends not only on the quartz crystal but also on the associated circuit and all capacitances in parallel with the device (eq. [14], Table 3). The measurement o f f , can be very useful in determining specific properties of the h o u n d i n g media such as in the case of electrolytes (26).…”
Section: Conductivity (D'nil)mentioning
confidence: 99%
“…These entities, bearing one of the reacting pairs, are attracted to the sensor surface by a magnetic field. Recently, Oyama and co-workers (14) reported that A-phage DNA can be covalently immobilized onto the gold surface of a TSM sensor and that dissociation and hybridization of immobilized DNA can be monitored by impedance analysis in the gas phase. The occurrence of immobilization and hybridization of DNA were then said to be confirmed by a small decrease off,,,,, (the frequency giving the maximum conductance) and increases of motional resistance.…”
Section: Introductionmentioning
confidence: 99%
“…f HG1/2 and f LG1/2 are the higher and lower frequencies at half-peak height in the G spectrum, and f B min and f B max are the frequencies at minimum and maximum B values, respectively, and all symbols are in their international units. In addition, Martin et al (2) have presented a series of equations of equivalent circuit parameters reflecting effects of the solution density (ρ L ) and viscosity (η L ), from which the relationship between R 1 and f 0 due to net changes in solution density and viscosity has been obtained as follows and validated experimentally (10)(11)(12),…”
Section: Introductionmentioning
confidence: 99%
“…Second, the swelling of polymer films in aqueous solution may cause the lose of part of the sensitivity and stability of the piezoelectric immunosensor. A silane layer is another useful coating, 7,8 however, because it can be integrated with the quartz crystal, the quartz-crystal resonator can not be used repeatedly.…”
mentioning
confidence: 99%