2005
DOI: 10.2116/analsci.21.281
|View full text |Cite
|
Sign up to set email alerts
|

Adsorption Behavior of Metal Ions onto a Bovine Serum Albumin (BSA) Membrane Monitored by Means of an Electrode-Separated Piezoelectric Quartz Crystal

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 23 publications
0
6
0
Order By: Relevance
“…The U–N bond length is longer than the lengths of other metal–nitrogen cations (i.e., Zn 2+ , Mg 2+ , Al 3+ , and Fe 3+ ions), leading to a depth effect for nitrogen combined with U VI ions. In summary, we proposed that the adsorption amount of U VI was mainly affected by Na + , Zn 2+ , Mg 2+ , and Ni 2+ ions in the coexisting ion aqueous solutions . Meanwhile, we also investigated the effect of individual ions on the removal efficiency of U VI by GO–BSA composites in aqueous solutions.…”
Section: Resultsmentioning
confidence: 97%
“…The U–N bond length is longer than the lengths of other metal–nitrogen cations (i.e., Zn 2+ , Mg 2+ , Al 3+ , and Fe 3+ ions), leading to a depth effect for nitrogen combined with U VI ions. In summary, we proposed that the adsorption amount of U VI was mainly affected by Na + , Zn 2+ , Mg 2+ , and Ni 2+ ions in the coexisting ion aqueous solutions . Meanwhile, we also investigated the effect of individual ions on the removal efficiency of U VI by GO–BSA composites in aqueous solutions.…”
Section: Resultsmentioning
confidence: 97%
“…We also applied membrane-based centrifugal ltration (molecular weight cut-off 3 kDa) as a general strategy to study the dissolution behavior of QD705. [41][42][43] This showed that even though the Te species released from the dissolution of QD705 were probably anionic, their adhesion to biomolecules was weak relative to that of cationic species, 44 with a À12% difference in slope (slope ¼ 0.8789) between the expected and measured ratios in the samples containing 0.5% rat serum (Fig. S6, ESI †).…”
Section: Establishment Of the Chemical Differentiation Methodsmentioning
confidence: 96%
“…Aer differentiating the diffusible ion species in samples prepared at various concentration ratios of Ag + /Ag total , Cd 2+ /Cd total , and TeO 3 2À / Te total (the total concentration for each element, including both the spiked metal ions and the intact MNMs), the slopes between the expected and practically measured ratios (ideally the value should be 1) for Ag + /Ag total , Cd 2+ /Cd total , and TeO 3 2À /Te total were 0.0008, 0.5726, and 0.8789, respectively. These values revealed that, due to interactions between the cationic metal species and sulfur-or phosphorus-containing compounds that were excluded by the 3 kDa membranes, 20,[134][135][136][137][138] the ability to use a physical size-discrimination strategy to separate diffusible metal ion species in the presence of an abundance of biomolecules was suppressed signicantly, especially for cationic Ag + and Cd 2+ species. Even though TeO 3 2À , a candidate species evaluated for QD dissolution, is anionic, and its binding to biomolecules should be relatively weak, 136 there was still an error of 12% between the expected and measured ratios when using the ultraltration method.…”
Section: Ultraltrationmentioning
confidence: 99%