2017
DOI: 10.1016/j.rinp.2017.08.012
|View full text |Cite
|
Sign up to set email alerts
|

Adsorption and inhibitive properties of sildenafil (Viagra) for zinc in hydrochloric acid solution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 38 publications
0
3
0
Order By: Relevance
“…Impedance spectra showed one time constant related to a single capacitive semi-circles, which indicated that the corrosion procedure was mostly controlled by charge transfer [32][33][34][35][36][37][38][39]. The obtained curves are very similar to each other, indicating that the mechanism of corrosion is not different after appending of BOD [40]. The diameter of Nyquist diagrams rises on rising of the BOD dose due to the creation of adsorbed layer of BOD on surface of P355 Cs.…”
Section: Resultsmentioning
confidence: 87%
“…Impedance spectra showed one time constant related to a single capacitive semi-circles, which indicated that the corrosion procedure was mostly controlled by charge transfer [32][33][34][35][36][37][38][39]. The obtained curves are very similar to each other, indicating that the mechanism of corrosion is not different after appending of BOD [40]. The diameter of Nyquist diagrams rises on rising of the BOD dose due to the creation of adsorbed layer of BOD on surface of P355 Cs.…”
Section: Resultsmentioning
confidence: 87%
“…In the acid medium the drug molecules may be protonated or may be neutral. Physisorption mechanism is due to: In the acid medium the drug molecules are protonated so, there is difficult for these protonated molecules to adsorb on the positive MS surface [56]. Chloride ions get first adsorbed on MS surface, the MS surface becomes negatively charged, and then the protonated Esomeprazole Magnesium Trihydrate molecules get adsorbed on the chloride layer.…”
Section: Mechanism Of Corrosion Inhibitionmentioning
confidence: 99%
“…, max f is the frequency at the impedance is maximal and the factor n is an parameter adjustable that regularly lies among 0.50 and 1.0 [40] [41] [42]. The overall figure of the plots is very like for all samples (in existence and nonexistence of inhibitor at unlike immersion times) representing that no exchange in the corrosion mechanism [43].…”
Section: Pp Testsmentioning
confidence: 99%