Additional adsorbed water in recycled concrete

Abstract: Recycling the decasting concrete catches more attention in the world. It depends on the strength for construction bearing to utilize recycled concrete (RC). Mixture ratio is one key factor deciding strength, which is supported by a crucial parameter: water-cement ratio. So the calculation of unit water use in RC is the hot topic, it is crucial that additional adsorbed water should be determined. It is appropriate to adopt the form of full (or part) coarse aggregate adding natural sand. In the case of mixed coa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0
1

Year Published

2008
2008
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 1 publication
0
4
0
1
Order By: Relevance
“…The water consumption for this test included net water consumption and additional water consumption, the latter of which is composed of the additional water consumption of recycled coarse aggregate and straw. The water absorption of recycled coarse aggregate is approximately three times that of natural aggregate, so additional water was supplied to the recycled coarse aggregate to minimize the impact of its high water absorption on the effective water-cement ratio [46,47]. To maintain the desired workability of concrete, around 10-13 kg of additional water per cubic meter of concrete was added for every 1% increase in the straw admixture during the experiment [35].…”
Section: Orthogonal Test Designmentioning
confidence: 99%
See 1 more Smart Citation
“…The water consumption for this test included net water consumption and additional water consumption, the latter of which is composed of the additional water consumption of recycled coarse aggregate and straw. The water absorption of recycled coarse aggregate is approximately three times that of natural aggregate, so additional water was supplied to the recycled coarse aggregate to minimize the impact of its high water absorption on the effective water-cement ratio [46,47]. To maintain the desired workability of concrete, around 10-13 kg of additional water per cubic meter of concrete was added for every 1% increase in the straw admixture during the experiment [35].…”
Section: Orthogonal Test Designmentioning
confidence: 99%
“…the effective water-cement ratio [46,47]. To maintain the desired workability of concrete, around 10-13 kg of additional water per cubic meter of concrete was added for every 1% increase in the straw admixture during the experiment [35].…”
mentioning
confidence: 99%
“…Therefore, the preparation procedures of natural aggregate concrete (NAC) are different to those of RAC. More specifically, the latter needs to consider the absorption of RA in the slurry, which is usually calculated by its saturated-surface-dried water absorption (W SSD ) [ 16 ]. Clearly, the accurate evaluation of the W SSD of RA is of great significance to control an effective water-to-binder (w/b) ratio (E w/b ) of RAC [ 17 ].…”
Section: Introductionmentioning
confidence: 99%
“…Tabsh and Abdelfatah (11) found that replacing natural coarse aggregates by recycled coarse aggregates (RCA) in concrete requires 10% of extra water in order to achieve the same slump. Owing to this particularity, the water withdrawal of unit volume of concrete with recycled aggregates should be increased on the basis of that of ordinary concrete (12).…”
Section: Introductionmentioning
confidence: 99%