2020
DOI: 10.3390/diagnostics10090639
|View full text |Cite
|
Sign up to set email alerts
|

Added Value of Subtraction SPECT/CT in Dual-Isotope Parathyroid Scintigraphy

Abstract: Background: Adding subtraction single-photon emission computed tomography/computed tomography (SPECT/CT) to dual isotope (I-123 and Tc-99m-sestamibi) subtraction parathyroid scintigraphy is not widely implemented. We aimed to assess the added value of dual isotope subtraction SPECT/CT over single isotope SPECT/CT as an adjunct to dual isotope planar pinhole subtraction scintigraphy. Methods: Parathyroid scintigraphies from 106 patients with an estimated total of 415 parathyroid glands who (1) were diagnosed wi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…However, dual-isotope subtraction parathyroid scintigraphy with 99m Tc-MIBI and 123 Iodide including SPECT/CT and planar pinhole imaging has a high diagnostic accuracy and is currently the most widely used method in eastern Denmark. The method has proven to be superior to both single-isotope MIBI planar and SPECT/CT imaging and to dual isotope subtraction scintigraphy with single isotope SPECT/CT [ 4 , 5 , 6 , 7 ].…”
Section: Introductionmentioning
confidence: 99%
“…However, dual-isotope subtraction parathyroid scintigraphy with 99m Tc-MIBI and 123 Iodide including SPECT/CT and planar pinhole imaging has a high diagnostic accuracy and is currently the most widely used method in eastern Denmark. The method has proven to be superior to both single-isotope MIBI planar and SPECT/CT imaging and to dual isotope subtraction scintigraphy with single isotope SPECT/CT [ 4 , 5 , 6 , 7 ].…”
Section: Introductionmentioning
confidence: 99%
“…One widely used method is dual-isotope subtraction parathyroid scintigraphy with 99m Tc-MIBI and 123 Iodide including SPECT/CT and planar pinhole imaging (Di-SPECT), which has a high diagnostic accuracy (sensitivity 82%-93% [5][6][7] ) and was proven superior to both singleisotope MIBI planar and SPECT/CT imaging and to dual-isotope subtraction scintigraphy with single isotope SPECT/CT (sensitivities 17%-89%). [5][6][7][8][9][10] Due to the high cost, time consumption (≤4.5 h) and radiation dose (≈13 mSv) alternative modalities such as positron emission tomography/computed tomography (PET/CT) using carbon-11-labelled choline ( 11 C-Choline) as the tracer (Choline PET) have been evaluated and found promising with sensitivity as high as 87%-97%. [11][12][13][14] Other widely used methods include 4D-CT and ultrasound, both of which have previously been found to have varying sensitivity, 55%-85% and 29%-81%, respectively.…”
Section: Introductionmentioning
confidence: 99%
“…Primary hyperparathyroidism (PHPT) is a common endocrine disorder with an estimated prevalence of about 0.23% among females and 0.085% among males; it is caused by abnormal increased secretion of parathyroid hormone, resulting in hypercalcemia. This disease is attributed in most of the cases (80-85%) to solitary parathyroid adenoma, followed by glandular hyperplasia in 10-15% of the cases, and double adenoma in 4% with malignancy accounts for only 1-3% of the cases [1][2][3].…”
Section: Introductionmentioning
confidence: 99%