2018
DOI: 10.12659/msm.908437
|View full text |Cite
|
Sign up to set email alerts
|

Added Value of NeuroGam Software Analysis in Single Photon Emission Computed Tomography Localization Diagnosis of Epilepsy in Interictal Stage

Abstract: BackgroundThis study aimed to investigate the added value of NeuroGam software analysis in the localization diagnosis of epileptogenic zone during interictal phase of seizures.Material/MethodsThe clinical data of 67 patients, clinically diagnosed as epilepsy, were analyzed retrospectively. Visual analysis and NeuroGam software analysis were used for independent analysis. The 2 methods were used to compare the efficacy indicator of the diagnosis of epileptogenic zone, and the receiver operating characteristic (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 27 publications
0
2
0
Order By: Relevance
“…With the help of the NeuroGam software package, the analysis of SPECT brain perfusion images becomes semiquantitative. [ 18 , 19 ] The examination results of brain SPECT are presented as numbers and tables which may minimize the interobserver and intraobserver variability.…”
Section: Discussionmentioning
confidence: 99%
“…With the help of the NeuroGam software package, the analysis of SPECT brain perfusion images becomes semiquantitative. [ 18 , 19 ] The examination results of brain SPECT are presented as numbers and tables which may minimize the interobserver and intraobserver variability.…”
Section: Discussionmentioning
confidence: 99%
“…Among MIMneuro (MIM Software Inc., Cleveland, OH, USA) analysis, STATISCOM, and SISCOM using SPM, STATISCOM showed the best performance for seizure onset zone localization, followed by MIMneuro and SISCOM, respectively (74). Quantitative analysis of 99m Tc-ECD using NeuroGam software (GE Medical System, Segami Corp., Columbia, MD, USA) showed a higher sensitivity for EZ localization than EEG, MRI, or visual analysis (75,76). Qualitative analysis of 99m Tc-HMPAO SPECT and quantitative analysis using SPM to compare patient's image data with a normal template by Z-score map and extract Z max of each voxel with the percentage of voxels with a Z-score higher than 2.5 could provide a diagnosis of nonconvulsive status epilepticus (NCSE) (77).…”
Section: Brain Perfusion Spectmentioning
confidence: 99%