Abstract:An analog spike detector circuit is presented, which adaptively generates a threshold level for spike detection based on hard-thresholding. Operation of the circuit was tested not only with a neural signal obtained from real in-vivo recording from a live animal, but also with a large sinusoidal baseline variation intentionally added to examine the capability of the circuit to track baseline variations as large as 50mV. The circuit runs at 3.3V supply voltage and dissipates 270 microW.
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.