2002
DOI: 10.1515/bmte.2002.47.s1b.656
|View full text |Cite
|
Sign up to set email alerts
|

Active Medical Implants and Occupational Safety - Measurement and Numerical Calculation of Interference Voltage

Abstract: Low frequency electric and magnetic fields may interfere with implanted cardiac pacemakers causing a life-threatening malfunction of the device. In order to assess the safety of workers in the vicinity of industrial electrical devices the interference voltage at the input port of a pacemaker is an important measure. In order to investigate the coupling of fields emanating from electrical devices a numerical method for the calculation of interference voltages is presented and applied to the investigation of hom… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…These equations only provide approximate results, due to being deduced from geometrically simplified homogeneous human models. The authors claim that the approximation shows results which are comparable to sophisticated models [ 11 , 12 ].…”
Section: Introductionmentioning
confidence: 94%
“…These equations only provide approximate results, due to being deduced from geometrically simplified homogeneous human models. The authors claim that the approximation shows results which are comparable to sophisticated models [ 11 , 12 ].…”
Section: Introductionmentioning
confidence: 94%
“…1.26 µT). Gustrau et al , 61 Seckler et al , 58 and Mattei et al 59 found a dependence of the induced voltage on lead configuration.…”
Section: Resultsmentioning
confidence: 94%
“…Gustrau et al 61 identified induced voltages at the PM terminals of 0.126 mV–131 mV (1 kHz–1 MHz, at 1 A/m, i.e. 1.26 µT).…”
Section: Resultsmentioning
confidence: 99%
“…The inhomogeneous field distribution is defined by the design, the geometry and the materials used of the field source which is in case of the Qi-A13-Board one of the three coils. To determine the induced voltage in previous studies phantom models [ 6 , 7 , 22 , 27 , 29 , 30 , 31 , 32 , 33 ], theoretical considerations [ 20 , 31 , 32 , 34 ] or numerical simulations [ 35 , 36 ] are used with different approaches for specific exposure conditions.…”
Section: Discussionmentioning
confidence: 99%