1999
DOI: 10.1016/s0022-1139(99)00111-6
|View full text |Cite
|
Sign up to set email alerts
|

Acidic 1-ethyl-3-methylimidazolium fluoride: a new room temperature ionic liquid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
126
0
1

Year Published

2000
2000
2017
2017

Publication Types

Select...
5
3

Relationship

3
5

Authors

Journals

citations
Cited by 162 publications
(128 citation statements)
references
References 11 publications
1
126
0
1
Order By: Relevance
“…[1][2][3] Our group has focused on fluorohydrogenate ILs (FHILs), which consist of organic cations and fluorohydrogenate anions, (FH) n F ¹ , where n represents the average number of HF ligands attached to the fluoride anion. One of the firstly developed FHILs, 1-ethyl-3-methylimidazolium fluorohydrogenate (EMIm-(FH) 2.3 F), exhibits high conductivity (100 mS cm ¹1 at 298 K), low melting point (208 K) and low glass-transition temperature (148 K), 4,5 making it a promising electrolyte for electrochemical devices.…”
Section: Introductionmentioning
confidence: 99%
“…[1][2][3] Our group has focused on fluorohydrogenate ILs (FHILs), which consist of organic cations and fluorohydrogenate anions, (FH) n F ¹ , where n represents the average number of HF ligands attached to the fluoride anion. One of the firstly developed FHILs, 1-ethyl-3-methylimidazolium fluorohydrogenate (EMIm-(FH) 2.3 F), exhibits high conductivity (100 mS cm ¹1 at 298 K), low melting point (208 K) and low glass-transition temperature (148 K), 4,5 making it a promising electrolyte for electrochemical devices.…”
Section: Introductionmentioning
confidence: 99%
“…One of the possible approaches is the usage of EMIm(HF) 2.3 F electrolyte which possesses high conductivity, low viscosity and chemical stability in air. [7][8][9][10] The proof of concept, that substantial discharge was possible when using EMIm(HF) 2.3 F electrolyte, was proposed in 2010 according to the following reactions: 11 Anode: Si + 12(HF) 2 Additionally, a screening of several anode materials -As-, Sband B-doped Si wafers -was performed, in which the cell potential at intermediate current densities as determined from potentiodynamic polarization measurements, was set as major criterion. The corrosion current densities as obtained by the Tafel fits from the polarization experiments for the different wafer types were also considered for the material selection.…”
mentioning
confidence: 99%
“…-was generated according the method of Hagiwara by condensing anhydrous HF onto 1-ethyl-3-methylimidazolium chloride [13] -in the 9:1 acetonitrile:water solvent. In one experiment, an aliquot of the aqueous iron(III) chloride solution was treated with approximately 1000 molar equivalents of hydrogen peroxide relative to Fe to ensure all of the iron in solution was iron(III) prior to mixing with pure acetonitrile.…”
Section: Iron Chloride Solutionsmentioning
confidence: 99%
“…This was surprising since the fluorohydrogenate anion forms a more stable complex than the chloride anion in the condensed phase [13]. This experiment was conducted using -(triflimide).…”
Section: Analysis Of Iron(iii) and Iron(ii) Chlorides Dissolved In [Ementioning
confidence: 99%
See 1 more Smart Citation