2018
DOI: 10.1088/1361-6560/aaf0bb
|View full text |Cite
|
Sign up to set email alerts
|

Achieving reliable coincidence resolving time measurement of PET detectors using multichannel waveform digitizer based on DRS4 chip

Abstract: Coincidence resolving time (CRT) is one of the most important physical-performance measures for positron emission tomography (PET), as reconstruction with accurate time-of-flight information enhances the lesion detectability in patient studies. Accordingly, various PET detector designs and high-performance front-end readout circuits have been actively investigated to improve timing performance. The resulting PET detectors are often evaluated using multichannel waveform digitizers for versatile data analysis of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 35 publications
0
5
0
Order By: Relevance
“…Inter-chip measurement was conducted to eliminate the highfrequency interference between adjacent DAQ channels within the DRS4 chip. 39…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Inter-chip measurement was conducted to eliminate the highfrequency interference between adjacent DAQ channels within the DRS4 chip. 39…”
Section: Discussionmentioning
confidence: 99%
“…The trigger value, which is a constant fraction of the peak height of the time signal, was swept during CTR measurement to achieve optimal timing performance in our measurement setup. Inter‐chip measurement was conducted to eliminate the high‐frequency interference between adjacent DAQ channels within the DRS4 chip 39 …”
Section: Methodsmentioning
confidence: 99%
“…The ultra-high-quality image constructed by SR-DL contains less image noise compared to conventional U-HRCT images. Many previous studies report that super-resolution and image noise reduction can be achieved simultaneously [ 10 , 13 16 ]. While U-HRCT shows superior image quality, the U-HRCT image obtained from inflated fixed cadaveric human lungs does not show lung microstructures as expected from its high spatial resolution.…”
Section: Discussionmentioning
confidence: 99%
“…The possibility to digitize the waveforms of all detector pulses was mentioned already. Compact and affordable digitizers with sampling rates >1 GHz exist that facilitate multichannel implementation of this approach (Cho et al 2011, Ronzhin et al 2013, Ashmanskas et al 2014, Park et al 2018. Time-multiplexing can be used to reduce costs, but leads to an increased DCR on the multiplexed channel (Grant and Levin 2015, Kim et al 2016, Bieniosek et al 2016a, Won et al 2016a.…”
Section: P1mentioning
confidence: 99%