2018
DOI: 10.1109/tpel.2017.2748221
|View full text |Cite
|
Sign up to set email alerts
|

Achieving Multiple Functions of Three-Phase Electric Springs in Unbalanced Three-Phase Power Systems Using the Instantaneous Power Theory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
30
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 30 publications
(30 citation statements)
references
References 22 publications
0
30
0
Order By: Relevance
“…The ES voltage injected in each phase is set to remove unbalance while minimizing the active power exchanged with the battery storage. In [89], a 3-phase ES is considered for voltage regulation and reducing unbalance based on the theory of instantaneous power which is verified experimentally. Reference [38] uses a modified instantaneous symmetrical component algorithm and hysteresis current control to operate ES in active power filter mode to mitigate harmonics, improve the power factor while regulating the mains voltage.…”
Section: F Unbalance Mitigationmentioning
confidence: 99%
“…The ES voltage injected in each phase is set to remove unbalance while minimizing the active power exchanged with the battery storage. In [89], a 3-phase ES is considered for voltage regulation and reducing unbalance based on the theory of instantaneous power which is verified experimentally. Reference [38] uses a modified instantaneous symmetrical component algorithm and hysteresis current control to operate ES in active power filter mode to mitigate harmonics, improve the power factor while regulating the mains voltage.…”
Section: F Unbalance Mitigationmentioning
confidence: 99%
“…Getting the absolute value of (17) gives According to (13), it can be obtained that the amplitude of V ES has a positive correlation with the absolute value of ΔP. Therefore, combined with the conclusion above, the amplitude of V ES should have a positive correlation with the absolute value of DEM -DEM-REF .…”
Section: Control Loop Of the Amplitude Of Es Voltagementioning
confidence: 99%
“…Yan S. et al [16] proposed a new topology of ES by using back-to-back converter in order to extend its operating range. Moreover, the criteria and conditions for minimizing the average and oscillating power of the 3-ph ES are introduced in [17]. ES is evaluated for improving the fault-ride through capability of the wind turbine generation system with fixed speed induction generator 2 Journal of Electrical and Computer Engineering in [18].…”
Section: Introductionmentioning
confidence: 99%
“…The versions above are also termed as ES generations since they are the milestones in the ES technology development. In addition to them, many other versions have been described [7]- [9]. Besides ACES, in recent times another kind of ES -referred to as DCES-has been studied to stabilize the supply voltage of the CLs connected to a DC microgrid [10], [11].…”
Section: Introductionmentioning
confidence: 99%