Aceclofenac-loaded pluronic F108/L81 mixed polymeric micelles: effect of HLB on solubilization

Abstract: Pluronic block copolymers have phase behavioural characteristics which are extensively studied for drug delivery applications. In this study, we explored hydrophilic pluronic F108 (HLB = 27), hydrophobic pluronic L81 (HLB = 2) and their mixed micelles acting as solubilising mediums for model drug aceclofenac. The drug solubilisation and interactions have been analysed using UV-visible spectroscopy, Fluorescence spectroscopy, Rheology studies, Fourier-transform infrared spectroscopy, Scanning electron microscop… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 50 publications
0
2
0
Order By: Relevance
“…For the sake of accuracy, CP measurements were performed at least three times, displaying a deviation within a range of ±0.2 °C. 15,18,25,33 The surface activity of 5% w/v F88 in the absence and presence of L81 with increasing concentration were determined using a tensiometer (Model-K9, KRU ̈SS GMbH, Germany). Surface tension (γ) readings were sustained following the dilution method and recorded accurately within ±0.1 mN m −1 after temperature equilibration at 30 °C (within ±0.1 °C).…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…For the sake of accuracy, CP measurements were performed at least three times, displaying a deviation within a range of ±0.2 °C. 15,18,25,33 The surface activity of 5% w/v F88 in the absence and presence of L81 with increasing concentration were determined using a tensiometer (Model-K9, KRU ̈SS GMbH, Germany). Surface tension (γ) readings were sustained following the dilution method and recorded accurately within ±0.1 mN m −1 after temperature equilibration at 30 °C (within ±0.1 °C).…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…The anticancer drug quercetin (QCT) was added in excess to the Pluronic solutions to create drug-loaded solutions. To calculate the concentration of dissolved QCT, the absorbance was measured using a HachDR6000 spectrophotometer between 200 and 800 nm. ,,, The sample solutions were filtered using a nylon syringe filter for each measurement (0.22 μm) to remove dust particles, if any. By employing well-known mathematical models, such as zero-order kinetics, first-order kinetics, and Higuchi, Hixson–Crowell, and Korsymeyer–Peppas models, the mechanism of QCT release from the blended micellar (5% w/v F88 as a function of L81 concentration) system was examined.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The ratio of both components is known as the hydrophilic–lipophilic balance (HLB) of surfactant agents and is related to the ability to interact with different drugs. F‐108 is a more hydrophilic compound than P‐123, presenting HLB values equal to 27 and 8, respectively 23,24 . The use of polymers with a higher hydrophilic or lipophilic character will allow obtaining micelles with dissimilar characteristics in order to select the best delivery system for NR and NRBr.…”
Section: Introductionmentioning
confidence: 99%
“…F-108 is a more hydrophilic compound than P-123, presenting HLB values equal to 27 and 8, respectively. 23,24 The use of polymers with a higher hydrophilic or lipophilic character will allow obtaining micelles with dissimilar characteristics in order to select the best delivery system for NR and NRBr.…”
mentioning
confidence: 99%