Accurate Xe Isotope Measurement Using JPL Ion Trap

Abstract: We report an approach for the reproducible and accurate compositional analysis of different mixtures of Xe isotopes using miniature Jet Propulsion Laboratory Quadrupole Ion Trap (JPL-QIT). A major study objective was to validate the recent instrumental improvements to the long-term operational stability under different pressures, temperatures, and trapping conditions. We propose that the present device can be used in certification of trace amounts of isotopes in mixtures dominated by one or more isotopes. Meas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
27
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(28 citation statements)
references
References 35 publications
1
27
0
Order By: Relevance
“…For the experimental results presented herein, this assumption is valid as all of the measurements were conducted at low pressures (P ≤ 2 × 10 − 6 Torr) and weak ionization currents (I e ≤ 5 × 10 − 6 A), strictly limiting the number density of confined ions (N i ≤ 2 × 10 5 cm − 3 ). In this regime, ion-ion collisions are a rare event that has been shown previously to affect only the low-mass wing of individual line profiles [21]. Under the stated assumptions, we consider the time evolution of a set of mutually noninteracting particles and numerically integrate a system of equations of motion:…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…For the experimental results presented herein, this assumption is valid as all of the measurements were conducted at low pressures (P ≤ 2 × 10 − 6 Torr) and weak ionization currents (I e ≤ 5 × 10 − 6 A), strictly limiting the number density of confined ions (N i ≤ 2 × 10 5 cm − 3 ). In this regime, ion-ion collisions are a rare event that has been shown previously to affect only the low-mass wing of individual line profiles [21]. Under the stated assumptions, we consider the time evolution of a set of mutually noninteracting particles and numerically integrate a system of equations of motion:…”
Section: Methodsmentioning
confidence: 99%
“…As illustrated in the xenon mass spectra found in Figure 1, the ion-neutral collisions at low pressures change the decay rate for the low-mass wing of the line profile. The central part of a profile remains unchanged and its full width at half maximum (FWHM) is further used in characterizing the mass resolution of the instrument [21]. This earlier modeling work demonstrated the variation of the mass spectral line shapes subject to trapping conditions.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The thermalizer maintains the stainless steel (SS) tube temperature at 70 • C to reduce deposition of sulfuric acid aerosols at the tube's inner surface. The voltage amplitude scan function for the RF drive is detailed in Madzunkov & Nikolic [15].…”
Section: Figure 1 (A) the Schematic Of Qit-ms-i (Quadrupole Ion Trapmentioning
confidence: 99%
“…When catering to a subset of scientific requirements, each instrument projects its performance based on response function parameters. The QIT-MS sensor is no exception, and details of its response function are found elsewhere [15]. We have also developed a simulation program [16] capable of predicting QIT-MS sensor performance under a wide range of operational parameters.…”
Section: Introductionmentioning